6.  Select OK to begin the update process or click Cancel to stop and exit. After the update 
process is completed you have to press OK so that the system will automatically restart. 
 
 
Alternative a firmware upgrade can be performed via the Web Client: 
-  Open Internet Explorer and type on the address bar the network IP address of the unit 
-  Log on by entering the User ID (default ADMINISTRATOR) and Password (default 
000000) 
-  Select the configuration mode by clicking on the “Configuration” button 
-  Select ‘System’ and then ‘Configuration’ 
-  Browse to the v2.0.7 firmware file name “600series.bin” (date 2013-02-08) 
-  Press the “Update” button 
Firmware will be automatically updated and unit will be restarted. 
 
3  DVR 600 Series firmware version history 
3.1  Version 1.1.0 
File name: 600series.bin (2010-11-30) 
 
Initial firmware version 
 
3.2  Version 1.2.0 
File name: 600series.bin (2011-03-28) 
 
This release includes the following improvement: 
-  PC application support (CC v3.32) of DVR 600 Series with firmware version 1.2.0. 
 
3.3  Version 1.3.2 
File name: 600series.bin (2011-09-27) 
 
This release includes the following improvement: 
•  Improve dome control using Intui keyboard. 
o
 
Immediate dome control when full screen is selected for cameras assigned for 
dome control. 
•  Quad image performance on Mon. A improved (diagonal lines were more jagged than in 
other multiscreens).  
•  Mon. B image performance improved (shown some flickering by certain monitor/camera 
combinations) 
•  Setting added to Auto delete video older than 3 days. For some countries this is required 
by law. 
•  SMTP port number was default on 587 when SSL is enabled.