Table 2: continued 
 
Modem II Report 
Description 
POINT BYPASS POINT  
001 (-024) 
Point 1 to 24 bypassed. Points can be bypassed from the keypad or from a remote 
programmer. Bypass Reports are only sent when Opening and Closing Reports are enabled in 
Section 6.0 Open/Close. 
RAM ACCESS OK 
Normal remote programmer session termination. 
RAM ACCESS FAIL 
Remote programmer made connection with control panel, but passcode was incorrect, ocall 
was not terminated with a Good-bye or Reset-Bye. 
RESTORAL REPORT 
POINT 001 (-024) 
Restoral Report from Points 1 to 24.  
RE-BOOT 
Control panel reset with the standby pin (Refer to Installation Manual) or a remote 
programmer. 
RF BATTERY LOW POINT 
001 (-024) 
Low battery in RF sensor, keypad, or arming device. 
RF BATT RESTORE 
POINT 001 (-024) 
Restored battery in RF sensor, keypad, or arming device. 
RF Rcvr Tamper  
SDI 7 (8) 
Enclosure tamper from premises RF receiver (D208RF, D216RF). 
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration. 
RF Rcvr Tamper 
Restoral  
SDI 7 (8) 
Enclosure tamper restoral from premises RF receiver (D208RF, D216RF). 
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration. 
RF Rcvr Trouble  
Device 7 (8) 
Trouble from premises RF receiver (D208RF, D216RF) 
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration. 
RF Rcvr Trbl 
Restoral  
Device 7 (8) 
Restoral from premises RF receiver (D208RF, D216RF) 
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration. 
RF TAMPER TROUBLE 
Tamper RF point, Controlled point, system off. 
RF TAMPER RESTORAL 
Tamper restoral, RF point. 
SERVICE START 
Installer mode entered (Stand-by locked down, installer passcode entered). 
SERVICE STOP 
Installer mode exited. 
SWINGER BYPASS POINT 
001 (-024) 
Points 1 to 24 bypassed automatically by the system after four alarms or troubles in one armed 
or disarmed period. You can program the Swinger Bypass feature to activate after less than 
four alarms or troubles. Refer to Swinger Count prompt in Section 1.0 System Configuration
Use the point code to program this feature by point. Refer to Section 11.0 Point Codes. 
TEST REPORT 
Automatic Test Timer Report. 
TROUBLE REPORT POINT 
001 (-024) 
Trouble on Points 1 to 24, Fire and Non-fire combined. 
USR CODE TAMPER 
This report transmitted after six attempts to enter an invalid passcode. 
WATCHDOG RESET 
System automatically reset. Call Bosch Security Systems if reports persist. 
 
 
0101
0101
0101
 
 
If you choose Modem Format, go to Section 5.0 Remote Programming. The prompts in the remainder 