Bosch 2000 User Manual

Page of 72
2000 Series | Program Entry Guide | 6.0 
Open/Close 
EN | 24 
 
Bosch Security Systems | 7/05 | 35114F 
 
Program 
Exit Tone 
Yes to enable the exit delay tone 
and excursion tone. 
Program
 Exit Tone
 No to disable the exit delay tone 
and excursion tone. 
5 No Delay 
Default: 
Part On
 
Selection:  Disabled, Part On, All On, All & Part
 
0 Disabled
 
1 Part 
On 
2 All 
On 
All & Part 
The 
No Delay
 prompt allows users to turn their 
system on with No Entry or Exit Delay (instant 
arming). If this prompt is set to Part On, users can turn 
their system Part On with No Delay by pressing the [0] 
key twice. 
If this prompt is set to All On,  users can turn their 
system All On with No Delay by pressing the [9] key 
twice. If this prompt is set to All & Part, users can turn 
their system All or Part On with No Delay. 
If this prompt is set to Disabled, users cannot turn their 
system on with No Delay. Entry and exit delay are 
always provided. 
Selecting 
Disabled for the 
No Delay
 prompt also 
disables the Excursion feature. Refer to the 
Excursion 
prompt. 
6 Excursion 
Default: 
Disabled
 
Selection:  Disabled 
All Step 
Part Step 
All & Part Step 
All Exit 
Part Exit 
All & Part Exit
 
0 Disabled
 
1 All 
Step 
2 Part 
Step 
All & Part Step 
4 All 
Exit 
5 Part 
Exit 
All & Part Exit 
Use the 
Excursion
 prompt to configure the system 
for either the Step Outside or Exit User features. 
6.1 Step 
Outside 
If you enable the Step Outside feature, pressing 
the [CLEAR] key at the keypad when the system 
is on with No Delay starts the exit delay tone (if 
Exit Tone
 is programmed Yes) and bypasses all 
points programmed for delay (Digit 1 of point 
code = 6 or 8). The rest of the system remains on. 
The tone and bypass remain until the user presses 
the [CLEAR] key a second time, returning the 
system to its fully on state. If a point is faulted 
when the user presses the [CLEAR] key the 
second time, the tone and bypass continue. The 
user must either clear the fault (close the door) or 
turn the system off with a passcode. 
The Step Outside feature allows users to pick up 
the morning paper or let the dog out without 
turning the system off. 
All Step:  Only allows users access to the Step 
Outside feature when the system is All On with 
No Delay (instant). 
Part Step: Only allows users access to the Step 
Outside feature when the system is Part On with 
No Delay (instant). 
All & Part Step: Allows users access to the Step 
Outside feature when either All or Part of the 
system is On with No Delay (instant).