Bosch 2000 User Manual

Page of 72
2000 Series | Program Entry Guide | 11.0 
Point Codes 
EN | 36 
 
Bosch Security Systems | 7/05 | 35114F 
 
4 Point 4 
Default: 
9820A
 
Selection: 
Refer to Table 5Table 6, Table 7Table 8, and Table 9 for selections for each digit in the point code.
 
9820A 
Door, No Delay 
No Delay Part point. Point arms when user turns the system 
Part (or All) On. Point does not start entry delay.  
Reports and alarm output enabled.  
Trouble on short when the system is off. Swinger bypass 
enabled.  
Alarm Report delay enabled. 
 
PT4 
PART/NO DLY 
5 Point 5 
Default: 
7820A
 
Selection: 
Refer to Table 5Table 6, Table 7Table 8, and Table 9 for selections for each digit in the point code.
 
7820A 
Motion Detector 
No Delay All point. Point only arms when user turns the 
system All On. Point does not start entry delay and is ignored 
during entry and exit delays.  
Reports and alarm output enabled.  
Trouble on short when the system is off. Swinger bypass 
enabled.  
Alarm Report delay enabled. 
 
PT5 
ALL/NO DELAY 
6 Point 6 
Default: 
7820A
 
Selection: 
Refer to Table 5Table 6, Table 7Table 8, and Table 9 for selections for each digit in the point code.
 
7820A 
Motion Detector 
Same response as 
Point 5
 
PT6 
ALL/NO DELAY 
7 to 24  Points 7 to 24 
Default: 
0000A
 
Selection: 
Refer to Table 5Table 6, Table 7Table 8, and Table 9 for selections for each digit in the point code.
 
0000A 
Point Disabled 
The system does not monitor disabled points. 
 
 
PT## 