Renewing fuel filter
Inspection III
If necessary, reduce fuel level with pump until fil-
ter is clear.
Loosen hose clip (1) and shift towards filter.
Detach line and remove filter together with line 
from the fuel tank.
Change fuel filter.
L
 Note:
Note direction of fuel flow on filter.
Reconnect line to pump. 
Install in the reverse order of removal.
L
 Note:
Gasket (2) must not close off the overflow hole. En-
sure recesses (arrows) in gasket are fitted in correct 
position.
Cleaning inductive pulse generator 
at rear wheel drive
Inspections I, III, IV
Release securing screw (1).
If necessary lever out inductive pulse generator 
and clean with rag.
Tightening torque:
Inductive pulse generator at rear wheel....... 2.5 Nm
LT000070
1
2
LT000080