Bay Technical Associates 525H User Manual

Page of 61
8
 
NOTE: Before you proceed with installation, make certain that the
device connected to the host port is setup to have the same
configuration as the multiport host port.  The H-Series multiports are
factory configured as follows:
Serial ports power up from the factory at:
9600 baud rate
8 word size
1 stop bit
No parity
XON/XOFF disabled
Control character:  
Control-T (14 Hex).
Terminating character:  
Carriage Return (0D Hex).
Data block length:  32 characters.
Mode of operation:  Mode 1 - Port expansion/sharing.
If the factory default configuration for all ports is not satisfactory for
your application, you must reconfigure the multiport by entering the
configuration mode (see 
Section 6).  The controlling or host device is
connected via cable to the host port on the H-models.  This is Port 5
of the 525H, Port 9 of the 528H and 529H, and Port 18 of the 5218H.
 Peripheral devices are connected via cable to any of the remaining
ports.  They need not be installed in any specific order.  Peripheral
ports not used may be left empty.