Buffalo Technology TeraStation TS-RXL User Manual
TeraStation User Manual
21
Change system to normal mode (previous page).
1
2
3
4
5
Note:
After the RAID array is changed, the TeraStation will perfom a RAID check that will take about 5 hours per TB. File
transfers will be slower during this period. While the “RAID ARRAY x Resyncing” message is displayed on the LCD
screen, do not turn off the TeraStation. If you turn it off, the RAID check will start over.
The [Confirm Operation] screen will appear.
6
Enter the number shown in the [Confirmation Number] field within 60 seconds, and click [Apply].
Follow the instructions displayed on the screen.
7
You have now set up a RAID 5 array. Turn to page 43 to create a shared folder.
Click the array you want to configure.
Select [RAID5].
1
Click [Create Raid Array].
2
Select hard disks (all 4 of them) to use in RAID5.
Using RAID 5 mode (4 hard drives)
Click [System] - [Storage] - [RAID Array] in the Web Admin interface.