Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 6.0  GV2AUX 
EN | 126 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
6.3 SDI 
Automation 
6.0 GV2AUX 
SDI automation defines the characteristics of a serial 
interface module (SIM) when used with home or 
business automation software. The SIM is a two-way 
SDI to a serial communication module that allows the 
control panels to send and receive information to and 
from an external software program.  
6.1 Introduction 
The GV2AUX Handler is used primarily for 
programming Enhanced Communication capabilities 
for the 9000GV2 Series Control Panels.  
“Enhanced communications” represents the ability to 
provide new communication functions for the control 
panels using the SDI bus including: 
The SIM can be a D9133, DX4010i, or 
DX4020 (configured to emulate serial 
communication). 
 
 
•  Routing control panel events to a network 
interface module (NIM). 
This automation protocol allows external software 
programs to interact and perform functions such as:  
 
A network interface module (NIM) can be 
• 
• 
• 
arming and disarming areas, 
a D9133TTL-E or a DX4020. 
 
changing user pass codes and names, and  
turning relays on and off. 
• 
• 
• 
• 
• 
• 
• 
• 
Communicating with remote programming 
software (RPS) using a network interface module 
(NIM). 
The items described in this section allow some 
simple configuration options. To receive the SIM 
automation protocol; however, you must contact 
Bosch Security Systems, Inc. Technical Support at 
(888) 886-6189. 
Communicating with a remote or local automatic 
software package. 
6.2 
RPS and D5200 Handler 
Requirements 
Enable SDI Auto 
In order to program the GV2AUX parameters for the 
control panels, you must use RPS version 3.8 or 
higher and a handler called GV2AUX. To add the 
GV2AUX Handler to your D5200 Programmer, call 
the Bosch Security Systems, Inc. Handler Update 
System at  
(800) 657-4584.  
Default: 
No 
Selection: 
Yes or No 
Yes 
Enable Automation software. 
No Disable 
Automation 
software. 
Changing this item to Yes enables the automation 
address (SDI Address 80). 
This handler currently has six sections:  
Baud Rate 
SDI Automation 
SDI RPS Parameters 
Default: 
9600 
Enhanced Communications 
300, 1200, 2400, 4800, 9600, 14.4 
Selection: 
SDI RPS/Enhanced Communication 
Configuration 
This item determines the baud rate between the 
serial interface module (SIM) and the external 
hardware connected to it. Since the SDI bus 
communicates at 9600 baud, keep this prompt at 
9600 baud. Pressing the [SPACE] bar on the D5200 
toggles through the available options. 
Miscellaneous 
Cross Point Parameters 
The handler required for these options is GV2AUX 
version 1.0 and above. It is available on the Handler 
Update System at Bosch Security Systems, Inc.