A# Area Type 
Default: 
Regular 
Selection:  Regular, Master, Associate, or Shared 
Regular 
Arms or disarms as an independent area. 
Master 
Does not allow arming for this area unless all associate areas with the same A# account 
number are master exit delay armed or master armed. CHK AREA displays if the associate 
areas are not armed. Exception: RPS allows master areas to be armed without all associate 
areas being in the armed state. 
A master area can be disarmed regardless of the armed state of the other areas in the account. 
Multiple master areas can be programmed in a single account. 
 
 
CC# Scope affects master arming. 
Area: When arming a master area that has CC# Scope set to Area for all 
keypads, all associate areas within the same account must first be armed 
 
independently by other means. 
Panel Wide or Account Wide: When arming a master area from a keypad 
with CC# Scope set to Panel Wide or Account Wide, all associate areas 
enters exit delay as soon as the master area is armed. If there is a shared 
area within the same account, it begins its exit delay after all associate 
areas are armed. 
 
 
 
 
 
Using the arming sked (S## Function 1) requires that you first use an 
arming sked to arm the associate areas before using an arming sked to 
arm the master area. Arming master areas with RPS, Keyswitch, or Auto 
 
Close parameters (refer to Sectio2.9.5 Open/Close Options on page 43) 
occurs before all associate areas are armed 
 
 
Associate 
Allows arming and disarming regardless of the armed state of the other areas with the same A# 
account number. Use this area type with a master area and associate it by using the same 
account number. 
 
Keypads assigned to associate areas, when used with shared areas, must 
have CC# Scope programmed. 
 
 
 
Shared 
Shared areas cannot be armed using a passcode, key switch, token or card, sked, or RPS.  
The scope of all associate areas must include the shared area(s) in order to view
faulted points.