Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 44 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
• 
• 
To suppress reports:  
Area 
Use Opening/Closing Windows to suppress 
reports for a specified period of time and then 
automatically turn them on again. 
Default: 
Selection:  1 to 8 
Use the Restricted O/C options. A Closing Report 
is sent if the user is force arming, sending 
duress, or bypass arming. An Opening Report is 
sent if the user is disarming during an alarm 
condition or unbypasses points when disarming. 
If the system is normal, no Opening or Closing 
Report is sent. 
Enter the area number you are programming. 
A# Acct O/C 
Default: 
No 
Selection:  Yes or No 
Yes 
Send Opening and Closing Reports 
by account. 
 
 
For the scheduled suppression of 
Opening and Closing Reports, refer to 
Section 5.1.1 Opening and Closing) to 
Use this selection if the control panel 
sends reports to an automation 
system that cannot interpret multiple 
Area Opening and Closing Reports, 
or if Modem Format is programmed 
as No in the Phone category (BFSK 
format is used and Opening and 
Closing Reports are enabled). 
define Opening and Closing Windows. 
Account Opening and Closing Reports 
Opening and Closing Reports are sent by account 
when the last area in a group of areas with the same 
account number(s) is armed. 
Area Opening and Closing Reports 
Closing Reports are sent for each area as it is armed. 
The account number is also sent for each area. 
An Account Opening Report is 
generated when the first area in an 
account is opened (disarmed). After 
the Account Opening Report is sent, 
disarming other areas in the account 
does not generate another Account 
Opening Report. An Account Closing 
Report is generated only when the 
last area in an account is closed 
(armed). Opening and Closing 
Reports for accounts do not contain 
any area information. 
Customizing Account Opening and Closing 
Reports 
You can eliminate area Opening and Closing Reports 
from selected areas in the account by programming 
A# Area O/C as No for those areas. 
Combination Account and Area Opening and 
Closing Reports 
To send both account openings and closings, and 
individual area openings and closings for all areas in 
the account, you must:  
Opening and Closing Windows 
affect Account Opening and 
Closing Reports:
 If an account 
opening or closing is generated while 
an Opening or Closing Window for 
this area is in effect, and Disable O/C 
in Window is programmed Yes, the 
report is not sent. Use the same 
opening and closing window times for 
all areas sharing the same account 
number. 
• 
• 
Program A# Acct O/C as Yes for all areas in the 
account. 
Program A# Area O/C as Yes for all areas in the 
account.  
Closing Reports: When areas in the account are 
independently armed, each area generates an Area 
Closing Report. When the last area is armed, it also 
generates an Account Closing Report. 
Opening Reports: When the first area in the account 
is disarmed, it generates an Account Opening Report 
along with an Area Opening Report. When the 
remaining areas in the account are disarmed, each 
area generates an Area Opening Report. 
No 
Do not send Opening and Closing 
Reports by account. 
Determines if this area generates Account Opening 
and Closing Reports. Program this item the same for 
all areas in the account. 
Area Only Opening Closing Supervision Features 
Use these features to supervise opening and closing 
activity by area. Auto Close, Fail To Open, and Fail 
To Close all work independently of the A# Acct O/C 
feature. To use these features, program O/C 
Windows.