Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 61 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
 
 
Master Arm Delay 
Perim Instant 
Default: 
Default: 
Selection: 
Selection:  Blank, E, or P 
Blank, E, or P 
 
Pass code: Required for all users 
with Master Arm Delay enabled for 
their authority level. 
Function Name 
Function 
No. 
Alternate 
Keystroke 
[COMMAND][2] 
Perimeter Instant 
Arm 
Enable: A user does not need a pass 
code to use [COMMAND][1]. 
Instant arms all perimeter points with point response 
that starts an instant alarm (refer to P## Pt Response 
in Section 
Blank 
Disable Master Arm Delay cannot be 
accessed in the function menu or 
started with a command even if this 
function is enabled for the user’s 
authority level. 
4.2 Point Responses on page 92) in the 
area where the keypad is assigned. Entry and exit 
delays are not provided with this arming function. 
This function causes a Perimeter Delay point to act as 
a Perimeter Instant point. 
 
For SIA CP-01 Compliance 
Function Name 
Function 
No. 
Alternate 
Keystroke 
Master Arm Delay  [COMMAND][1] 
Use this arming function to master arm disarmed 
areas. If enabled, the following arming choices are 
available to the user with this authority. 
Mstr Arm Inst 
Default: 
Blank 
Selection: 
Blank, E, or P 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Master Arm 
Instant 
[COMMAND][1][1] 
Use this arming function to master arm instant areas 
that are disarmed. Entry and exit delays are not 
provided with this arming function. This causes a 
Perimeter and Interior Delay point to act as an Instant 
point. 
For SIA CP-01 Compliance 
 
 
This feature is not allowed to be used 
with SIA CP-01 compliant installations. 
 
This feature is not allowed in SIA CP-01 
compliant installations. 
 
Perim Delay 
Default: 
Selection: 
Blank, E, or P 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
[COMMAND][3] 
Perimeter Delay 
Arm 
Delay arms all Perimeter points in the area where the 
keypad is assigned. Entry and exit delays are 
provided with this Arming function. This function does 
not cause a Perimeter Instant point to act as a Delay 
point. 
Watch Mode 
Default: 
Selection: 
Blank, E, or P 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
6 Watch 
Mode 
[COMMAND][6] 
This function informs you when a perimeter point or 
interior point that is programmed as P## Watch Point 
is faulted while the area is disarmed. Interior points do 
not emit a Watch Tone if the area is perimeter armed. 
This function provides keypad audible or visual and 
optional relay activation (refer to A # Watch Mode in 
Section 2.13.1 Area Relays on page 79).