Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 67 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
Custom Functions 
Authority Level 
C Function 128 [through 143] 
Default: 
 
Default: 
Selection:  1 to 14 
Selection:  Blank, E, or P 
Enter the number of the authority level you want to 
program. Authority Level 15 (Service Passcode) 
cannot be edited. 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
To determine the L## default values on 
128 through 
143 
Enable Custom 
Functions 128 
through 143 
(Menu function 
only) 
, refer to the User 
pages 67 through 76
When enabled, Custom Function determines if a pass 
code is required when accessing a custom function 
from the menu list. ENTER PASSCODE (or Enter 
Passcode + Enter Key on the D1260) appears when 
this function is pass-code protected. If a command 
within the Custom Function is pass-code protected, 
the keypad displays ENTER PASSCODE (or Enter 
Passcode + Enter Key on the D1260) and waits for 
the user to enter a valid pass code before proceeding 
with the rest of the Custom Function. If a pass code is 
not entered within 10 sec, the Custom Function times 
out and the display returns to idle text. 
2.11.4  Authority Level Selections 
Use Section 2.11.4 Authority Level Selections on 
page 67 to determine which Authority Level can 
access keypad functions that are pass-code 
protected. Selecting Enable items in the Authority 
Level section is not necessary if the keypad function 
is disabled or enabled. Each individual function has 
two selections you can use for the authority level you 
are programming. 
Press the [SPACE] bar to scroll through the 
selections. Press [ENTER] when the correct selection 
appears in the display. 
 
Table 28: Authority Level Selections 
 
Authority 
Level 
Description 
Blank 
Disabled: This function is not 
authorized for the user who is 
assigned this authority level. 
Enabled: This function is 
authorized for the user who is 
assigned this authority level. 
 
 
Interface section for the GV2MAIN 
 
Handler in the program record sheet. 
 
L## Disarm 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
 
Function Name 
Function 
No. 
1 Disarm 
Use the disarming function to disarm areas that are 
master armed or perimeter armed. If enabled, the 
following disarming choices are available to the user 
with this authority: 
•  DISARM ALL: Disarms all areas within the CC# 
Scope of the keypad being used by accessing 
the Function Menu and the authority level of the 
user performing the function. 
•  DISARM AREA: Disarms only the displayed 
area. 
Many options are available for arming 
and disarming. Selecting an option 
depends on A# Area Type and CC# 
 
Scope. Read the definitions of area type 
in Section 2.9 Area Parameters on page 
5 anCC# Scope in Section 2.10.1 
Keypad (Command Center) Assignment
 
on page 51