1.3 
Guide to Programming Options 
 
To acquire an update for your D5200 
Programmer, call the Bosch Security 
Systems, Inc. Handler Update System at 
(800) 657-4584. Make a separate phone 
call for each handler.  
Use an analog telephone line with the 
D5200. The D5200 dials only pulses. 
Refer to Section 10 Updating Handlers in 
the D5200 Programmer Operation Manual 
(P/N: 74-06176-000-B) for details on 
updating handlers. 
This guide is set up in a specific order. Related 
program entries are grouped together in modules as 
they appear in the specific product handlers. The 
handler and the programming module are listed at the 
top of each page to help you find specific 
programming prompts. 
This guide shows the programming options for each 
product handler. Each option is listed with:  
 
• 
• 
• 
• 
• 
The Program Item Prompt: Each prompt is 
shown as it appears in the D5200 Programmer 
[refer to the D5200 Programmer Operation 
Manual.
(P/N: 74-06176-000)] or the Remote 
Programming Software (RPS). Refer to the RPS 
Installation and Operation Guide 
(P/N: 
4998141259). For space considerations, some 
prompts must be abbreviated in the Programmer 
display. In these cases, the meaning of the 
prompt is explained below the prompt 
• 
• 
• 
• 
To connect the D5200 Programmer to the control 
panel: 
1.  Close the reset switch, located in the upper 
right corner of the control panel and labeled 
S1 Reset, to place the D9412GV2 or 
D7412GV2 Control Panel in the standby 
mode. 
2.  Connect the Molex® connector at one end of 
the cord to the connector labeled PROG on 
the PCB and PROG CONN on the faceplate. 
Program Entry Default Setting: Because 
defaults are set for the typical installation, 
programming each prompt might not be 
necessary. Review the default entries in the 
program record sheet shipped with the control 
panel to determine which prompts must be 
programmed. 
To retrieve the current control panel configuration, 
press the [RECV (COPY)] key on the D5200 at 
the NEWRECORD prompt. Refer to the D5200 
Programmer Operation Manual
 (P/N: 74-06176-
000) for detailed information. 
Program Entry Selections: Only the selections 
listed can be used for a particular program item.  
To write new configuration information for the 
control panel, press the [SEND (LOAD)] key at 
the NEWRECORD prompt. Refer to the D5200 
Programmer Operation Manual
 (P/N: 74-06176-
000) for detailed information. 
Program Entry Description: Describes the 
various entry selections. Read the descriptions 
carefully to avoid improperly programmed 
equipment. 
To disconnect the D5200: 
Custom Programming: Select custom 
programming (Yes or No) to expand 
programming modules within the D5200. 
Programming Custom as Yes allows parameters 
for special applications to be visible in the 
programmer. 
1.  Disconnect the the Molex® connector. 
2.  Open the reset switch.  
 
When the reset switch is opened, the 
control panel reboots and resumes 
normal operation within 5 to 25 sec.  
1.4 Programming 
the Control Panel 
with the D5200 Programmer 
 
Table 4:  Programming Error Displays 
 
Display Description 
INCOMPATIBLE 
PANEL 
You are connected to the 
wrong control panel or using 
the wrong handler. Check the 
faceplate for the model 
number and the handler title. 
CHECK 
CORD/RESET PIN 
Check the cord and the reset 
pin 
 
 
 
Caution: Do not connect the D5200 to 
the PROG connector without closing the 
reset switch. Doing so causes SDI ## 
TROUBLE and CALL FOR SERVICE to 
display on the keypads. Door controllers 
also activate, depending upon the SDI 
failure DIP switch setting.