Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 75 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
• 
• 
• 
• 
• 
• 
The keypad shows point text when invisible points 
are tested. 
The test ends when all points are tested, or if the 
test times out after 10 min of no activity. 
Local event printing occurs without alarm 
annunciation or reports sent to the central station 
receiver. 
The D1255 Keypad shows a sequential count and 
text related to the point after each point is 
activated and restored. 
The keypad shows All PTS TESTED. An All 
Points Tested Event is sent to the central station 
receiver (if programmed) when the last point is 
tested. 
Walk Start and Walk End Reports are sent to the 
central station receiver for the beginning and end 
of the test (if programmed in phone routing). 
 
Custom Functions 
L## C Function 128 [through 143] 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
128 through 
143 
Enable Custom 
Function 128 
through 143 
(Menu function 
only) 
Execute the desired Custom Function. 
Report Levels 
L## Force Arm 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
A user with this authority level can Force Arm. 
L## Area O/C 
Default: 
Refer to the program record sheet 
Selection: 
Blank or E 
Generates Opening and Closing Reports if the area 
where this authority level is assigned sends Opening 
and Closing Reports. 
L## Restricted O/C 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
Generates an Opening Report if a bell is ringing or a 
Closing Report when force or bypass arming. The 
area where this authority level is assigned must be 
programmed for restricted openings and closings 
(refer to the A# Restrictd O/C prompt in Section 2.9.5 
Open/Close Options
 on page 43. 
L## Perimeter O/C
 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
Generates Perimeter Opening and Closing Reports if 
the area where this authority level is assigned sends 
Perimeter Opening and Closing Reports. Refer to the 
A# Perimeter O/C prompt on page 47 in Section 
2.9.5 Open/Close Options
L## Send Duress 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
Generates a Duress Report if the area where this 
authority level is assigned sends duress. (Refer to the 
A# Duress Enable prompt on page 39 in Section 
2.9.5 Open/Close Options.) 
L## Passcode Arm 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
Arm an area by entering a pass code and pressing 
[ENTER]. 
L## Passcode Disarm 
Default: 
Refer to the program record sheet 
Selection:  Blank or E 
Disarm an area by entering a pass code and pressing 
[ENTER].