Bosch Appliances Video Game Controller D9412GV2 User Manual

Page of 158
D9412GV2/D7412GV2 | Program Entry Guide | 3.0  RADXUSR1/RADXUSR2 
EN | 84 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
This window does not affect tokens and 
3.0 RADXUSR1/RADXUSR2 
cards. It only affects the pass code of the 
master user. 
 
• 
• 
• 
• 
• 
3.1 
Pass Code or Token Worksheet 
 
These programming items assign: 
 
When using the Add/Change User 
a pass code to user groups 001 to 249, 
function at the keypad, the authority levels 
and the changes made affect the master 
areas by authority level, and 
 
user’s pass code and the entire group’s 
a User Group Window. 
token or cards. 
Two handlers in the D5200 Programmer are used to 
program the users: 
When using the ACCESS CTL LVL 
function at the keypad, the whole group is 
RADXUSR1 Handler programs users 000 to 124. 
affected by whether or not the level is on 
or off for access control functions only. 
RADXUSR2 programs users 125 to 249 
(D9412GV2 only). 
When using the DELETE USER? 
3.1.1 User 
Groups 
function, the whole group is deleted. You 
cannot delete each user within the group 
For the D9412GV2, there are 249 groups (99 groups 
for the D7412GV2) consisting of one user with a pass 
code and token (master) and three users with tokens 
or cards but not a pass code (sub-user). All users in 
the group share the same authority level as the 
master user. 
individually. Use the ADD/CHG USER? 
function to change a user token or card 
instead of deleting the whole group. 
3.1.4 User 
Name 
Each user group can be assigned one U### Name
This name is logged and sent to the central station 
for all the users in the group. The user ID is used to 
differentiate which user’s token or card was 
executed. 
3.1.2 Pass 
Codes 
In a control panel with factory default settings, only 
the master user has an assigned pass code. A pass 
code can be three to six digits. Entering three digits in 
User ### chooses the user. Programming the U001 
Passcode
 assigns a pass code to the master user. 
Sub-users cannot use the pass code. Do not assign 
tokens or cards to User ID 0 (zero), which is reserved 
for the service pass code. 
Passcode Tamper 
If a user enters six consecutive invalid pass codes at 
the same keypad, the control panel sends a User 
Code Tamper report to the cental station. The invalid 
pass code count resets when a valid passcode is 
entered at the same keypad. Refer to R# Usr Code 
Tamper in Table 11 on page 18 for information on 
enabling this report. 
The passcode tamper condition is also reported in a 
manually initiated Extended Test Report and to RPS 
through control panel diagnostics. As a result, the 
tamper condition is reset after the successful 
completion of a manual report or when disconnecting 
from an RPS session. The tamper condition is not 
reset when the control panel reboots. 
3.1.3 User 
Group 
Window 
Use U### User Group to enable and disable the 
U### Passcode for up to eight different time periods 
throughout the day. Assign the number (1 to 8) 
programmed in U### User Group to a User 
Windows #
. If the user is outside a window, 
COMMAND DISABLED appears on the keypad after 
the user enters the pass code and presses [ENTER]. 
When using a D1260 Keypad, User 249 
text is used for contact information text 
(such as telephone numbers). If a D1260 
 
is installed on the system, do not use 
User 249 for user ID information. 
3.1.5 Tokens 
and 
Cards 
The master user assigned the pass code can also be 
assigned a token or card by programming the U### 
Mstr Site
 and U### Mstr Crd Data
Three more tokens or cards are assigned to the user 
group for sub-users using the U### SU# Site and 