D9412GV2/D7412GV2 | Program Entry Guide | 4.0  RADXPNTS 
EN | 94 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
P## Entry Delay 
P## Ent Tone Off 
Default: 
Refer to the program record sheet 
Default: 
No 
Selection:  5 sec to 600 sec 
Selection: 
Yes or No 
Use this option to enter the amount of entry delay 
time that a user has after faulting a Controlled point 
(P## Type 1, 2, 3) with a delayed response (D) (P## 
Pt Response
) of 4, 5, 6, 7, or 8. DISARM NOW 
appears for the duration of the time programmed 
when the point is faulted in the delay condition. 
Disables the entry delay tone when 
this perimeter point is faulted.  
Yes 
This is intended for use with points 
set to P## Type 1 (Perimeter). 
A tone sounds at keypads when this 
point starts entry delay. 
No 
 
The D1255 alternates between DISARM 
This option enables and disables the entry delay 
warning tone for this point. 
NOW and the point text of the point that 
caused the area to enter into entry delay. 
 
Do not set points to No if they are actually 
used to notify the user to disarm the 
If this time expires before disarming, or if the point is 
configured with an instant response (I), an alarm 
occurs. 
system. The possibility of false alarms 
 
increases if the entry delay warning is not 
used. 
 
Make entries in 5 sec increments. The 
 
 
programmer does not allow off-increment 
entries. 
When the control panel is in Entry Delay, entering a 
valid Passcode disarms the system as soon as the 
last digit of the Passcode is entered. No other keys 
are required. When the control panel is in Exit Delay 
or is armed, entering a valid Passcode must be 
followed by the [ENTER] or [ENT] key. 
 
 
If another Perimeter or Interior Follower 
Delay point trips while the area is already 
in entry delay, the control panel adjusts 
the delay time to the Delay point with the 
least amount of delay time. 
When a user enters an area, a Perimeter 
point is faulted and the entry delay starts. 
If an interior point must fault during entry 
delay to allow the user to disarm the area 
at a keypad, program P## Type as 3 
(Interior Follower). 
For SIA CP-01 Compliance: 
P## Entry Delay
 must be between 30 sec and 
240 sec. 
Entry Tone can also be turned off when 
programming your CC Entry Tone, in 
Section 2.10 Keypad (Command Center) 
 
on page 51, that allows you to manage 
the tone by keypad. 
 
You might want to disable the entry tone 
in high security applications where you do 
not want to annunciate entry delay. 
 
P## Silent Bell 
Default: 
No 
Selection: 
Yes or No 
Activate the Silent Alarm Relay when 
this point enters into alarm. Keypads 
do not sound the alarm tone for Non-
fire points. 
Yes 
No 
Activate either the Fire Bell relay or 
Alarm Bell relay and sound the alarm 
tone at keypads when this point 
enters into alarm. If this is a Fire 
point, it activates the Fire Bell relay 
programmed in Relay Parameters. 
Otherwise, it activates the Alarm Bell 
relay. The amount of time and 
pattern of the relay activation is 
programmed by area in Bell 
Parameters. 
 
To meet UL 864 requirements, set this 
parameter to No