Bosch Appliances Stereo Amplifier LBB 1925/10 User Manual

Page of 4
Impedance
>1 kohm (mic); >5 kohm (line)
S/N (flat at max volume)
>63 dB (mic); >70 dB (line)
S/N (flat at min volme/muted)
>75 dB
CMRR
>40 dB (50 Hz – 20 kHz)
Headroom
>25 dB
Speech filter
-3 dB @ 315 Hz, high-pass,
6 dB/oct
Phantom power supply
16 V via 1.2 kohm, (mic mode only)
Line input
3 x
Connector
Cinch, stereo converted to mono,
unbalanced
Sensitivity
200 mV
Impedance
22 kohm
S/N (flat at max volume)
>70 dB
S/N (flat at min volume/
muted)
>75 dB
Headroom
>25 dB
Master output
1 x
Connector
3-pin XLR, balanced
Nominal level
1 V
Impedance
<100 ohm
Tape output
1 x
Connector
Cinch, 2 x mono
Nominal level
350 mV
Impedance
<1 kohm
Headphone output
1 x
Connector
6.3 mm jack stereo, signal mono
Nominal level
3 V
Impedance
<100 ohm
Zone relays
5 A
Contacts voltage
250 V
Contacts current
8 A
Interconnection input /
emergency
1 x
Connector
3-pin XLR, balanced
Sensitivity
200 mV (interconnection),
100 mV to 1 V adjustable
(emergency)
Impedance
>10 kohm
VOX threshold
45 mV (emergency)
Interconnection output
1 x
Connector
3-pin XLR, balanced
Nominal level
200 mV
Impedance
<100 ohm
Relay contacts
30 V, 1 A
DC supply output voltage
24 V, 250 mA max
Mechanical
Dimensions (H x W x D)
100 x 430 x 270 mm
(19" wide, 2U high)
Weight
Approx. 5 kg
Mounting
Standalone, 19" rack
Color
Charcoal
Environmental
Operating temperature
-10 ºC to +55 ºC (14 ºF to +131 ºF)
Storage temperature
-40 ºC to +70 ºC (-40 ºF to
+158 ºF)
Relative humidity
<95%
Ordering information
LBB 1925/10 Plena System Pre-Amplifier
6-zone, 2-channel distribution system unit with call
and BGM (background music)
Order number 
LBB1925/10
 
3 | LBB 1925/10 Plena System Pre-Amplifier