Bosch KTS 200 User Manual

Page of 12
Bosch Diagnostics
1 689 989 001
2007-05-30
|
Maintenance  |  KTS 200 | 25
  | 25
6.
Maintenance
6.1
Cleaning
The housing and the display on the KTS 200 may only 
be cleaned with soft cloths and with neutral cleaning 
agents. Do not use any abrasive cleaning agent or rough 
cleaning cloths.
6.2
Spare and wearing parts
Description
Order number
System tester KTS 200 (green)
1 687 023 279
System tester KTS 200 (blue)
1 687 023 428
System tester KTS 200 (gray)
1 687 023 429
Power pack
Power supply lead
(<)
1 687 023 889
1 684 461 106
USB connecting lead, 1 m
(<)
1 684 465 491
OBD diagnostic lead, 1.5 m
(<)
1 684 465 555
Wall bracket
1 681 320 082
(<)
Wearing parts
7.
Technical data
7.1
General data
Property
Value/Range
Operating voltage
7 VDC — 34 VDC
Power consumption 
approx. 7 Watt
LCD display
3,5"
320 * 240 Pixel
Dimensions (L x W x H)
140 x 220 x 40 mm
Weight (without connecting leads)
600 g
Operating temperature
5 °C – 40 °C
Relative humidity
90 % (at 25 °C)
Protection class
IP 30
7.2
Interface protocols
The following interfaces and their associated protocols 
are supported for control unit diagnosis in compliance 
with ISO 15031:
ISO 9141-2 (communication lines K and L)
SAE J1850VPW und SAE J1850PWM
(communication lines BUS+ and BUS-)
CAN ISO 11898 ISO 15765-4 (OBD) 
(communication lines CAN-H and CAN-L)
CAN Single Wire
CAN Low Speed
7.3
Power pack
Property
Value/Range
Input voltage
90 VAC — 264 VAC
Input frequency
47 Hz — 63 Hz
Output voltage 
15 V
Operating temperature
0 °C — 40 °C
R
R
R
R
R
en