Bosch Appliances Microphone 2.4 User Manual

Page of 15
DCN Next Generation 2.40 Release Notes 
en | 8 
 
Bosch Communications Systems | 2007 March 
5  Release 2.01 
5.1  General 
5.1.1  Release Date 
May 30th 2005 
5.1.2  Firmware/FPGA versions 
 
Product 
FPGA SW 
FW 
DCN-CCU 1.06 
2.01.0989 
3.10.1716 
DCN-CON 
DCN-CONCS 
1.0 2.00.XXXX 
-- 
DCN-CONFF 
DCN-CONCM 
1.0 1.00.XXXX 
-- 
DCN-DDB --  1.3.XXXX 
-- 
DCN-DDI 1.0 
-- 
-- 
DCN-FCS 1.0 -- 
-- 
DCN-IDESK 1.3  1.10.XXXX 
-- 
LBB 4402/00 
-- 
2.01.0989 
3.10.1716 
5.1.3  Compatibility restrictions 
The following versions are not compatible with this 
release: 
 
Product 
FPGA SW 
FW 
DCN-CCU 
≤1.00 -- 
-- 
LBB 4120 
1.0 
-- -- 
5.2  Errata 
5.2.1  Quick Reference Card DCN-IDESK 
The message functionality operates as follows: 
When the interpreter desk receives a message, the 
message is displayed directly on the display. When 
pressing the message button the message will be 
erased from the display. 
 
The message is not displayed when pressing the 
message button again. 
5.2.2  Integrus Manual: standby function 
When switching off the DCN Next Generation CCU, 
the Integrus transmitter indicates “Network Error” 
and not “standby”. However, the radiators do switch 
to the standby mode.  When the DCN Next 
Generation CCU is switched on again, the Integrus 
transmitter and the radiators return to the “on” 
mode. 
5.3  Known limitations 
5.3.1  System: reset of units after connecting 
new units to a trunk 
When a device to a LBB 4114/00 or LBB 4115/00, 
which is connected to the DCN-CCU Central 
Control Unit, it can happen that all units in that 
same trunk reset. After reset the units come back to 
default settings. The units in the trunk will not reset 
if a unit is connected to a Tap-off outlet of a LBB 
4115/00 Splitter protected. 
If it is important that the channel selectors are not 
reset to default in above described situation: use 
the auto restore function of the channel selector. 
See the Installation and User Instruction for how to 
set the auto restore function. 
 
If it is important that you can connect and replace 
each unit during operation, without the above 
described reset behavior: power the units with the 
DCN-EPS Extension Power Supply Unit. The DCN-
EPS Extension Power Supply Unit is less prone to 
the inrush current 
5.3.2  Use of Developers Toolkit 
The developers toolkit provided on this CD-ROM 
can only be used with Windows 2000. 
5.3.3  Text “starting” remains on CCU 
In a system with an Audio Expander and an 
Integrus transmitter, the text “starting” can remain 
on the display of the CCU after start up. On the 
display of the Audio Expanders 'No Network' is 
flashing. 
Switch the network mode of the Integrus transmitter 
to enabled and the problem will be solved. 
5.3.4  Network mode disabled results in faults 
When the network mode of a transmitter is set to 
disabled, while connected to a DCN Next 
Generation system, noise on the loudspeakers in 
the DCN Next Generation system can occur. 
 
Switch the network mode of the Integrus transmitter 
to enabled and the problem will be solved.