Blue Sea Systems Automobile Battery Charger PN 7712 Leaflet

Page of 2
The ML-Series Remote Battery Switch provides high-current carrying and switching under load. 
The Remote Battery Switch should be installed close to the battery banks to avoid voltage drop. 
Install a single pole double throw (SPDT) or single pole single throw (SPST) control switch in a convenient 
location near other electrical controls or companionway to allow quick access in the event of an emergency 
(see Illustration on reverse).*
The Manual Control Override Knob provides:
•  an added level of safety that allows manual ON-OFF control with or without power
•  LOCK OFF for servicing the electrical system
 
 
ML– Series
Remote Battery Switch (RBS)
PN 7712 / PN 7712B /
 
PN 7714 / PN 7714B
 
980010060 Rev.002
• Magnetic Latch (ML)—draws very low current (<13 mA in the ON state and <8 mA in the OFF state) and draws 
  moderate current for very short time when changing state
• Silver alloy contacts provide high reliability for switching live loads
• Manual control override knob provides an added level of safety allowing control with or without power, 
  and offering LOCKED OFF capability for servicing
• LED output to remotely indicate switch state 
• Tin-plated copper studs for maximum conductivity and corrosion resistance
• Label recesses for circuit identification
• PNs 7712 and 7714 include a Remote Control Switch PN 2155
RBS Specifications  
7712, 7712B
 
7714, 7714B
 
 
 
Cranking Rating 
 
See Table Below 
See Table Below
Intermittent Rating  
 
See Table Below 
See Table Below
Continuous Rating  
 
See Table Below 
See Table Below
Amperage Operating Current  
When changing state <7A from Main  
When changing state <4A from Main
       
 
 
contacts returns to negative (blk) wire 
contacts returns to negative (blk) wire
       
 
 
In “ON” state 13mA, In “OFF” state 8mA  When “ON” 13mA, When “OFF” 8mA
Voltage Maximum Operating 
16.5V DC Max. 
32V DC Max.
Live Current Switching 
 
300A @ 12V DC—10,000 Cycles 
150A @ 24V DC—10,000 Cycles‡
Mechanical Endurance 
 
100,000 Cycles 
100,000 Cycles
Control Circuit Voltage 
 
9–16.5V DC   
8–32V DC
Terminal Stud Size 
 
3/8"-16 (M10)  
3/8"-16 (M10)
Maximum Terminal Stud Torque 
140 in-lb (15.5 N•m)  
140 in-lb (15.5 N•m)
Ring Terminal Size 
 
3/8", M10  
 
3/8", M10
Terminal Ring Diameter Clearance  1.18" (30.0mm)  
1.18" (30.0mm)
Regulatory Meets ISO 8846 and SAE J1171 external ignition protection requirements, Rated IP66
Remote Control Switch 2155 Specifications
Action 
 
 
SPDT, ON-ON
Maximum Operating Amperage       20A @ 12V DC | 15A @ 24V DC
Seals             
 
Internal & External Gasket Panel Seal
Operating Temperature Range     -40°C to 85°C
Mounting Hole            
 
1.450"x 0.830" (36.00mm x 21.08mm)
LED Rating                 
 
100,000 hours 1/2 life, 20 mA @ 14V
Regulatory Meets ISO 8846 and SAE J1171 external ignition protection requirements, Rated IP67
Marine Electrical Products
PN
Termination
Manual 
Control
Control 
Circuit
Remote Control 
Switch Included
7712
Tinned Wires
Yes
12V DC
SPDT, ON-ON
7712B
Tinned Wires
Yes
12V DC
-
7714
Tinned Wires
Yes
24V DC
SPDT, ON-ON
7714B
Tinned Wires
Yes
24V DC
-
Overview of Application
To connect battery bank to load, 
or combine battery banks
With Override Knob in (REMOTE position), 
push button until latched (Push to Latch On).
To disconnect battery bank from 
load, or isolate battery banks that 
are connected
Rotate Override Knob to right to release button 
from Latch On mode (button pops up). Rotate 
Override Knob to left (REMOTE position). 
To prevent remote operation
Rotate Override Knob to right 
(LOCK OFF position).
To secure for servicing
With Override Knob in (LOCK OFF position),
pass cable tie through hole.
1
2
Wire Size (AWG)
Cranking 10 sec. 
Cranking 1 min. 
Intermittent 5 min.  Continuous (UL 1107)
2/0
2,000A
750A
400A
225A
4/0
2,000A
750A
400A
300A
2x (4/0)
2,500A
1,100A
700A
500A
To connect battery bank to load, or combine 
battery banks
Set remote switch 2155 to position marked “ON”. 
Remote LED indicates closed connection.
To disconnect battery bank from load, or 
isolate battery banks that are connected
Set remote switch 2155 to position marked “OFF”.
425 Sequoia Drive 
 
Bellingham, WA  98226  USA
p 360.738.8230
p 800.222.7617 USA and Canada
f  360.734.4195
www.bluesea.com
Remote LED Indicator embedded in PN 2155 SPDT ON-ON Contura Switch
indicates Remote Battery Switch state or condition as follows:
LED INDICATION
REMOTE BATTERY SWITCH STATE OR CONDITION
LED is OFF
Remote Battery Switch is OFF
LED is ON
Remote Battery Switch is ON
LED double blinking ON-OFF
Manual override--check Remote Battery Switch for switch states.
OR Remote Battery Switch mechanical failure
 
Predicted performance
* Although a SPST switch may be used if desired, use of a SPDT switch improves immunity to inadvertent 
  switching if the controls become damp.
Emergency Manual Control Override Operations
The remote LED embedded in PN 2155 indicates a closed connection between battery bank and load, or 
between two battery banks when used as an emergency cross-connect.
Remote Operation. PN 2155 (SPDT, ON-ON) Remote Control Contura Switch in the ON position can either 
connect the battery bank to the load or combine two battery banks. In the OFF position it can either 
disconnect a battery bank from a load or isolate two batteries from each other.