SERVICING INSTRUCTIONS 
23 
TEMPERATURE CALIBRATION 
 
PRECAUTIONS:
 
The technician is exposed to hot surfaces     
 
 
 
 
 
 
during this procedure.  Wear appropriate      
      protective 
clothing. 
 
FREQUENCY:
   
Monthly, at a Minimum;  or, As Needed
 
 
TOOLS:
   
 
 
Digital Pyrometer with Oven Probe, 
      Protective 
Gloves 
 
  THE FOLLOWING PROCEDURE IS TO BE               
PERFORMED BY QUALIFIED PERSONNEL ONLY
 
 
1.  With the oven empty, clamp the thermocouple sensor in the center 
 
of the middle rack: 
 
a.  Pass the thermocouple sensor wires through the corner of the 
 
 
door gasket and close the door. 
 
b.  Plug the sensor into the Pyrometer. 
 
2.  Turn the OVEN POWER (V.01) switch to ON.  Turn the FAN 
 switch 
(V.02) 
to 
HI
 
a.  Rotate the TIME control (V.06) until the time digits (V.05B) on 
 
 
the display read "60:00". 
 
b.  Rotate the TEMP control (V.07) until the temp digits (V.05A)  
  display 
375º. 
 
c.  Press the START TIMER key (V.08). 
 
3.  Allow the oven to heat for 45 minutes.  If, after 45 minutes, the  
 
temperature display reads between 370º and 380º, the calibration 
 
is satisfactory.  Otherwise: 
 
a.  Rotate the TIME controller until the time digits (V.05B) on the 
  display 
read 
"00:00". 
 
b.  Rotate the TEMP control until the temp digits (V.05A) display 
 
 
between 400º and 500º. 
 
c.  Press and hold the START TIMER (V.08) key for five seconds. 
 
d.  Turn either the TIME or TEMP control until the desired offset is 
  displayed. 
 
e.  Press the ACTUAL TEMP (V.09) key to exit.  Procedure is  
  complete. 
 
CAUTION: 
HOT SURFACE 
 
Exposed surfaces can be hot 
to the touch and may cause 
burns. 
509 3059
36 O
p
M
 W
V
OC-G
136