Beyerdynamic UHF Wireless System Opus 900 User Manual

Page of 164
76
5.
Trouble Shooting
5.1
NE 900 Diversity Receiver
5.2
Handheld and Beltpack Transmitter
• Power supply is interrupted, power 
supply unit is not connected to the mains 
and / or to receiver
• Connect the receiver to AC power
• Switch on the transmitter
• Adjust the correct frequency with the
ACT function
• Check the antenna cables
• Input amplifier of the connected mixer is
overloaded
• Use the gain control of the mixer or 
adjust the volume
Distorted sound
No reception
No function
Problem
Possible Cause
Solution
• Transmitter is not switched on
• Transmitter works on a different 
channel
• Defect in the antenna cables with 
remote antennae
“CLIP” indication on
receiver
• Transmitter is overloaded
• Reduce the sensitivity of the 
transmitter or increase the distance 
between microphone and sound 
source.
No sound, RF-indication is
okay, AF- indication is
missing during 
modulation
• Wrong indication caused by strong 
interference signals
• No microphone connected to TS 900 
beltpack transmitter
• Choose another receiving channel
• Connect a suitable microphone
• Transmitter and receiver have different 
frequencies
• Insufficient battery voltage
• Poor battery contact, battery inserted 
incorrectly
• Check if transmitter and receiver 
have the same frequency
• Replace the batteries or recharge 
them, if you use rechargeable 
batteries
• Check the battery and insert it again
• Transmission distance between transmitter
and receiver is too big
• Reduce the distance between 
transmitter and receiver
No RF-indication at the
receiver
• Interference from other transmitters
• Two transmitters are on the same 
frequency
• Battery of the transmitter is too weak
• Switch off the other transmitters
• Change the frequency of one 
transmitter
• Replace the batteries
Noise/chirping
No function
Problem
Possible Cause
Solution