Installation
Note: Before installation, please inspect the Unit.  
Make sure that nothing inside the package is damaged.
A. Connect to AC Utility Power
 
Plug in the AC cord to a wall outlet. Please make sure there are 
no devices plugged into the Unit. Check to see whether the 
“SITE WIRING FAULT” indicator is lit. If it is lit, please have the 
utility wiring inspected by an electrician. 
B. Charge the Battery
 
For best results, charge the battery for eight hours prior to initial use. The 
Unit charges its battery whenever it is connected to the utility power.  
C. Turn on the Unit
 
Turn on your Unit by depressing the “On/Off” button for approximately 
two seconds. You will see the green indicator light come on. 
D. Plug in Power Devices
 
Plug your devices into the AC outlets on the Unit. To use the Unit as a 
master on/off switch, make sure all of the loads are switched on.
 
Caution: Never connect a laser printer or scanner to the 
backup outlets along with other computer equipment. 
A laser printer or scanner draws significantly more 
power when in use than when idle. This may overload 
the Battery Backup
.
E. Connect the Phone/Fax/Modem Lines
1.  Connect a single phone/fax/modem line into the surge-protected outlets 
on the side of the Unit. The RJ11 modular outlets accept standard  
single-line telephone connections. 
2.  Plug one end of the phone cable into your telephone wall jack and plug 
the other end into the jack marked “IN”. You may now plug a phone, fax, 
or modem into either of the two jacks marked “OUT”. (See Fig. 3)
Fig. 3
Note: This connection is optional but highly recommended as phone/fax/
modem lines often carry dangerous surges and spikes. The Unit works 
properly without a phone/fax/modem connection.
Caution: The phone/fax/modem protection feature could be rendered inoperable 
if improperly installed. Make sure that the telephone line from the wall is plugged 
into the connector marked “IN”, and the devices to be protected (phone/fax/
modem) are plugged into the connector marked “OUT”. 
F Connect the USB (Universal Serial Port) Communication  
       Port (See #4 on Fig. 2)
 
A USB port is provided to relay the signal to support Windows. To fully utilize 
the Belkin Automatic Power Management Software, you will need to connect 
the Unit to your computer. Connect the USB cable to the Unit, then connect the 
other end to your computer’s USB port.
G.   Install Belkin APM Software
a)  System requirements
• 
128 MB RAM of memory at least (256MB is recommended)
• 
256 colors and 800 * 600 resolution or above display is recommended
• 
160 MB of disk space or above
• 
An available communication port (RS-232 Serial Port or USB port) is needed 
while connecting to UPS with a special connecting cable.
• 
For Mac OS X, Linux or Unix operating system, the user must have the access 
authority as the super user
• 
TCP/IP protocol must be installed to support network management
• 
The user needs to have the access authority as the administrator
b)  Platforms supported by Belkin APM Software.
The following operating system (OS) is arranged by the alphabetical order:
Introduction
Thank you for purchasing the Battery Backup with Surge Protection (the 
Unit). Each year, frequent natural and man-made power disturbances 
disrupt the power supplied to your home or office electronics. These power 
problems place your hardware, software, and data at risk. Belkin Battery 
Backups provide an uninterruptible power supply (UPS) with advanced 
features as the industry-leading solution.
Package Contents
You should have received the following:
 
1 –  Battery Backup unit
 
1 –  Installation CD containing Belkin Automatic Power Management Software 
 
(the Belkin APM Software) for Windows
®
 
 
1 –  USB Cable
 
1 –  Phone-Line Cable
System Requirements
The Battery Backup can be used without the software with any computer using 
up to a 17" CRT or LCD monitor. You do not have to have the software installed to 
utilize the battery-backup outlets.
To fully utilize the Battery Backup and its software, your computer must be running 
one of the following operating systems: Windows XP / 2003 / 2000 / ME / 98 / NT 4.0 
(SP6) or Linux
, and have a USB port.
Overview   |   Features and Functions
Before installation, please inspect the Unit upon receipt. Make sure that 
nothing is damaged.
Your Battery Backup features three LED indicators. Each is marked by a 
power icon; please familiarize yourself with this chart, as it will assist you in 
the use of your Battery Backup. (See #4 on Fig. 1)
3. The “On/Off” button has four functions: (See #3 on Fig. 1)
1.  Turns on the Unit. Depress button at least two seconds. The green  
light illuminates.
2.  Cold start function. If the battery is charged, the Unit will work without 
being plugged into an outlet. Depress and hold the key for at least two 
seconds to turn on the Unit. 
3.  Silence function. During “On Battery Mode”, the audible sound  
can be turned “ON” or “OFF” by depressing the switch for less  
than 1.5 seconds.
4.  Battery test function. During “On-Line Mode”, depressing the switch  
for less than 1.5 seconds causes the Unit to perform a battery test in 
backup mode. 
Overview   |   Side Panel 
1. AC Input Power Cord (See #1 on Fig. 2)
Provides power to your Battery Backup.
2. Phone/Fax/Modem Surge Protection (See #2 on Fig. 2)
The phone/fax/modem lines are surge-protected. There are one input jack 
and two output jacks. This allows you to split one telephone connection to 
two separate devices. 
3. AC Breaker (Circuit Breaker; see #3 on Fig. 2)
Should a power overload occur, the circuit breaker triggers the Unit to turn 
off AC power. To restore power, depress the “circuit breaker” button to reset, 
then depress the “Power” button. 
4. USB Communication Port (See #4 on Fig. 2)
The Unit features a USB communication port. Installation of the cable and the 
Bulldog Plus Software, which allows the Unit to connect to your computer, is 
optional. The Unit will provide backup power whether or not the cable and 
software are installed; however, without them you will be unable to utilize the data 
management product features. 
Battery Replacement Procedure
Replacement requires removing the battery cover plate on the back or 
bottom of the Battery Backup. No tools are needed. To replace the battery:
1.  Push the connector in the arrowhead direction.(Fig.1) 
2.  Remove the battery cover plate and the battery from the Unit(Fig.2)
3.  Disconnect the insulated connectors from the battery terminals, and replace 
the new battery pack. (Fig. 3)
4.  Close the battery cover plate, then lock the connector. (Fig.4).
Overview   |   Alarms
Backup (Slow Alarm)
When the Unit is in “backup” mode (running on battery), the YELLOW LED 
illuminates and the Unit emits an audible alarm. The alarm stops when the 
Unit returns to normal online operation.
Low Battery (Rapid Alarm)
In “backup” mode, when the battery energy runs low, the Unit beeps rapidly 
until it either shuts down from a depleted battery or returns to normal  
online operation.
Fault (10 Seconds Continuously)
When the Unit fails, it emits an audible alarm continuously for 10 seconds to 
warn of a fault condition. Disconnect the equipment prior to checking it.
Overview   |   Storage
Storage Conditions
Store the Unit covered and upright in a cool, dry location with its battery fully 
charged. Before storing, charge the Unit for at least six (6) hours. 
Extended Storage
During extended storage in environments where the ambient temperature 
is +5° F to +86° F, charge the Unit’s battery every six (6) months. During 
extended storage in environments where the ambient temperature is +86° F 
to +113° F, charge the Unit’s battery every three (3) months.
Note:
Overview   |  Important Safety Instructions
Please save this User Manual!
It contains important operating instructions and warranty information 
pertaining to your Battery Backup.
Please save or recycle the packaging materials!
The Unit’s packaging was designed with great care to provide protection 
during shipment and delivery. These materials are invaluable if you ever have 
to return the Unit for service. Damage sustained during transit is not covered 
under the warranty.
Overview   |   Top Panel
1. Surge-Protected-Only Outlets (See #1 on Fig. 1)
These outlets do not provide battery power during an outage. Do not  
plug surge protectors or power strips into the battery-backup outlets  
(i.e., daisy-chaining). 
Equipment such as computer peripherals, printers, fax machines, or desk 
lamps may be plugged into these outlets. The On/Off button does not control 
these outlets.
2. Battery-Backup Outlets (See #2 on Fig. 1)
Only data-sensitive equipment such as a computer, monitor, and external 
drive should be plugged into these outlets. Battery power is automatically 
provided in case of a power outage. Power (AC or battery) is not supplied to 
these outlets when the Unit is switched off. (Do not plug surge protectors or 
power strips into the battery-backup outlets.)
Caution: Never connect a laser printer or scanner to the backup outlets 
along with other computer equipment. To do so might overload the Unit.
Overview   |   Technical Specifications 
Chart 1
  Indicator  
Condition 
Meaning
On-Line 
 Solid Green 
The Unit is operating and supplying the utility  
   
 
power to connect loads.
On-Battery 
* Flashing Yellow 
Low Battery
Replace Battery
UPS Fault 
 Solid Yellow
Site Wiring Fault 
 Solid Red
When the Unit is operating from battery:
1.  The light blinks every 10 seconds if the 
Unit is operating on battery mode.
2.  The light illuminates rapidly every  
1 second if the Unit’s battery is very 
nearly depleted. 
When the Unit is operating and supplying 
the utility power to connect loads, the LED 
flashes and the buzzer emits a sound every 
1 minute to indicate the Unit’s battery needs 
to be replaced.
The “SITE WIRING FAULT” LED illuminates 
when one of the following conditions exist: 
1.  Open or high resistance ground 
2.  Hot and neutral polarities reversed
The LED lights steadily and the buzzer 
beeps for 10 seconds if a  
battery fault is found.
Fig. 1
Fig. 2
              Model   
  F6H375-USB 
F6H550-USB  
 z
Input 
Rated Capacity 
375VA/200W 
550VA/300W
 
Rated Voltage 
 
104–137VAC
 
Phase/Freq. 
 
Single-phase 60Hz
Output 
Voltage 
 
Step wave
 
Frequency 
 
60Hz
Battery 
Backup Time 
Desktop  
Desktop computer +17" 
 
 
computer   
monitor 13 min. 
 
 
+15" monitor  
          
 
 
10 min. 
 
Recharge Time 
 
16 hours to 90% 
Environment 
Temperature 
 
0~40°C
 
Humidity 
 
0~90%
Safety 
Safety 
 
UL1778 / c-UL
Regulation 
EMI 
 
FCC Class B
 
EMS 
IEEE C62.41 category A/IEC1000-4-5 / Level 2
Appearance 
Dimensions  
 
134 x 89 x 357mm 
 
(W * H * D)  
 
 
Net Weight 
                         2.9kg.   
3.1kg.
All specifications are subject to change without prior notice.