White Rodgers 1F86ST-0471 User Manual

Page of 8
3
Displays the power level of the
2 “AA” batteries:
       indicates good power level.
       indicates batteries at about
half power. “Cambiar       ” 
(Change       ) indicates batteries 
are low and should be replaced 
with 2 new premium brand “AA” 
Alkaline batteries.
Time
Day of Week
Setting 
Temperature
Room
Temperature
Temperature Up/Down
RETENER
Button
SISTEMA
Button
VENT
Button
SISTEMA
Indicator
VENT 
Indicator
MENU/PROGRAMA/ARRANCAR
Button
Home Screen Description
Figure 4 – Home Screen Display
Figure 5 – Programming & Confi guration Items
10
1
2
3
4
5
6
7
8
9
THERMOSTAT QUICK REFERENCE 
9
 Displays 
"Bomba de Calor" (Heat Pump) when 
system is confi gured as Heat Pump thermostat.
10
 Displays 
"Retener" (Hold) in programmable mode 
when in "Retener" (Hold) mode. Displays Light Bulb 
in non-programmable mode.
Programming and Confi guration Items 
1
  Flame icon ( ) is displayed when the system is in
CALOR mode. Snowfl ake icon (
) is displayed when  
the system is in FRIO mode.
2
 The 
word 
RETENER is displayed when the thermostat  
is in the RETENER (Hold) mode. Temporal RETENER 
is  displayed when the thermostat is in a Temporal 
RETENER 
(Temporary Hold) mode.
3
 Displays 
"Cambiar Frio" (Change Filter) when the 
system has run for the programmed fi lter time period 
as a reminder to change or clean your fi lter.
4
 Displays 
"Ajuste" (Set) for setpoint when in Run 
Program mode.
5
 Displays 
System Mode (Calor, Frio, Auto, Off) or Hora
(Time) in menu mode.
6
 Displays 
Fan Mode (On, Auto) or "Arrancar" (Run) in 
Menu mode of "Ahorra" (Saving) in Cool Savings
TM
 
Mode.
7
 Displays 
"Arrancar Programa" (Run Schedule), 
"Programa" (Schedule), or "Menu".
8
 Displays 
"Guardar" (Save) when Cool Savings
TM
 is 
working.
Refer to equipment manufacturers' instructions for specifi c system wiring information. After wiring, see CONFIGURATION 
section for proper thermostat confi guration. Refer to 37-6754 for 1F80-0471/1F86-0471 wiring diagram specifi cations.
WIRING CONNECTIONS 
TERMINAL DESIGNATION DESCRIPTIONS
Terminal Designation Description
Terminal Designation Description
O/B.................
Y......................
W....................
G.....................
(SS) Power closed for 3 wire zone 
(HP) Changeover valve for heat pump
Compressor Relay
Heat Relay
Fan Relay
RH...................
RC...................
C.....................
Power for Heating
Power for Cooling
Common wire from secondary side 
of cooling system transformer or 
heat only system transformer