Troubleshooting
This section covers the most common problems and corrections with this type of 
machine. 
WARNING! DO NOT make any adjustments until power is disconnected and 
moving parts have come to a complete stop!
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Machine does not start or a 
breaker trips.
1.  Emergency  stop  push-button  is 
engaged/faulty.
2.  Power supply switched OFF or is at 
fault.
3.  Start  capacitor  is  at  fault  (W1772 
only).
4.  Motor  connection  wired  incorrect-
ly.
5.  Thermal  overload  relay  has 
tripped.
6.  Wall fuse/circuit breaker is blown/
tripped.
7.  Contactor  not  getting  energized/
has burnt contacts.
8.  Wiring is open/has high resistance.
9.  Emergency  stop  push-panel  is 
stuck/switch is at fault.
10. Motor is at fault.
1.  Rotate  clockwise  slightly  until  it  pops  out/replace 
it.
2.  Ensure  power  supply  is  switched  on;  ensure  power 
supply has the correct voltage.
3.  Test/replace if faulty (W1772 only).
4.  Correct motor wiring connections.
5.  Unplug machine, open magnetic switch cover, turn 
amperage dial on Thermal Protection Circuit Breaker 
to a higher amperage setting. 
6.  Ensure  circuit  size  is  suitable  for  this  machine; 
replace weak breaker.
7.  Test for power on all legs and contactor operation. 
Replace unit if faulty.
8.  Check  for  broken  wires  or  disconnected/corroded 
connections, and repair/replace as necessary. 
9.  Free  push-panel  from  binding;  replace  faulty 
switch.
10. Test/repair/replace.
Machine  stalls  or  is  over-
loaded.
1.  Feed rate too fast for task.
2.  Workpiece material is not suitable 
for this machine.
3.  Run  capacitor  is  at  fault  (W1772 
only).
4.  Belt(s) slipping.
5.  Motor  connection  is  wired  incor-
rectly.
6.  Motor bearings are at fault.
7.  Machine is undersized for the task.
8.  Contactor not getting energized or 
has poor contacts.
9.  Motor has overheated.
10. Motor is at fault.
11. Air  circulation  through  the  motor 
restricted.
1.  Decrease feed rate.
2.  Only  cut  wood  products;  make  sure  moisture  con-
tent is below 20% and there are no foreign materials 
in the workpiece.
3.  Test/repair/replace (W1772 only).
4.  Replace bad belt(s) as a matched set, align pulleys, 
and re-tension.
5.  Correct motor wiring connections.
6.  Test  by  rotating  shaft;  rotational  grinding/loose 
shaft requires bearing replacement.
7.  Use  new  sandpaper  with  appropriate  grit;  reduce 
the feed rate/depth of sanding.
8.  Test for power on all legs and contactor operation. 
Replace if faulty.
9.  Clean off motor, let cool, and reduce workload.
10. Test/repair/replace.
11. Clean off motor to provide normal air circulation.
Drums  run  backwards 
(W1773 only).
1.  Two of the power wires are reversed 
(W1773 only).
1.  Switch two of the current carrying wires at the main 
power block (W1773 only). (