White Rodgers 1F78-144 White-Rodgers 70 Series Non-Programmable Single Stage Thermostat Wiring Reference

Page of 1
www.white-rodgers.com
90
TECHNICAL HELP
W905
Clip for
Hydronic
System
W904
Clip for
Celsius Display
W905
W904
ELEC GAS
Electric/Gas
Switch
W
RH
B
RC
G
O
Y
CONFIGURATION AND
TYPICAL WIRING DIAGRAMS
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Cool only, 3-wire, single transformer systems
Cooling
System
Fan
Relay
RC
O
B
JUMPER
WIRE
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Heat only, 3-wire, single transformer systems
TRANSFORMER
Heating
System
Fan
Relay
Y
RC
JUMPER
WIRE
For  2-wire  Heat  only 
attach to RH and W
NOTE
O
B
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Heat/cool, 4-wire, single transformer systems
TRANSFORMER
Heating
System
Fan
Relay
Cooling
System
RC
JUMPER
WIRE
RED  jumper  wire  (provided 
with  thermostat) 
must  be 
connected  between  thermo-
stat's 
RH  and  RC  terminals 
for  proper  thermostat  oper-
ation with this system.
NOTE
O
B
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Heat/cool, 5-wire, two-transformer systems
HEATING TRANSFORMER
Heating
System
Fan
Relay
Cooling
System
RC
24 VAC
120 VAC
Hot
Neutral
COOLING TRANSFORMER
O
B
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Heat pump with cool active reversing valve
TRANSFORMER
Reversing
Valve*
RC
O
B
JUMPER
WIRE
Compressor
Contactor
JUMPER
WIRE
* Reversing valve is energized when the
   system switch is in the COOL position
Fan
Relay
RH
Y
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Heat pump with heat active reversing valve
TRANSFORMER
Reversing
Valve*
RC
O
B
JUMPER
WIRE
Compressor
Contactor
JUMPER
WIRE
* Reversing valve is energized when the
   system switch is in the HEAT position
Fan
Relay
1F78-144
1F78-151
CONFIGURATION