Woodstock SHOP FOX W1677 User Manual

Page of 64
-13-
W1677/W1711 10" Table Saw
EL
EC
TR
IC
A
L
ELECTRICAL
We do not recommend using an extension cord with your 
machine. If you have no other choice, use the following 
guidelines:
•  Use cords rated for Standard Service
•  Never exceed a length of 50 feet
•  Ensure cord has a ground wire and pin
•  Do not use cords in need of repair 
Extension Cords
Grounding
This machine must be grounded! Verify that any exist-
ing electrical outlet and circuit you intend to plug into 
is actually grounded. If it is not, it will be necessary to 
run a separate copper grounding wire, of the appropri-
ate size, from the outlet to a known ground. Under no 
circumstances should you connect your machine to an 
ungrounded power source or electrocution or severe 
shock could occur.
220V Operation
The Model W1677/W1711 is prewired for 220V operation. 
Always connect this machine to a dedicated circuit with a 
verified ground, using the recommended circuit size and 
power connection method stated below.
Never replace a circuit breaker with one of higher amper-
age without consulting a qualified electrician to ensure 
compliance with wiring codes. If you are unsure about 
the wiring codes in your area or plan to connect your 
machine to a shared circuit, you may create a fire haz-
ard—consult a qualified electrician to reduce this risk.
Electrocution  or  severe  shock  could 
occur if machine is not grounded.
L6-20 P
L6-20 R
L6-30 P
L6-30 R
Figure 11. Plug & receptacle examples.
Model
Operating Voltage Amp Draw Min. Circuit Size
Plug/Receptacle
Extension Cord
W1677 Series
220V
18 Amps
20A
NEMA L6-20
12 Gauge
W1711 Series
220V
25 Amps
30A
NEMA L6-30
8 Gauge
Replacing  an  existing  circuit  breaker 
with  one  rated  for  higher  amperage 
may result in a fire. Get help from an 
electrician  if  your  circuit  is  too  small 
for the machine.