Wind Crest VEN060I Leaflet

Page of 2
© 2006 Wind Crest by CNP Industries  
 
Install Quick Specs are for planning purposes only.  Please refer to the detailed installation 
instructions, prior to making any cutouts.
   
 
Internally Mounted Ventilators – Install Quick Specs 
VEN060I  
 
   
Installation Type & Discharge Direction   
Mounted in hood. Can be mounted for vertical 
or horizontal discharge, depending on the 
hood specified (see individual hood 
specifications) 
 
CFM Rating 
  640 CFM – Single Blower 
1280 CFM – Dual Blower applications 
 
Minimum Duct Size  
  8” round @ 640 CFM 
10” round @ 1280 CFM 
   
Maximum Equivalent Straight Duct Length 
50 feet 
 
Equivalent Straight Lengths 
•  1 foot of 8” or 10” duct = 1 foot 
•  1 foot of 3 ¼” x 14” rectangular = 1 foot 
•  8” round 90 degree Elbow = 5 feet 
•  10” round 90 degree Elbow = 3 feet 
•  Wall or Roof Cap = 2 feet 
 
Standard 
Features 
    
•  Adaptable to all Wind Crest hoods 
•  Brushed alumized steel construction 
•  Thermally protected, permanently 
lubricated motor 
•  Dynamically balanced 5 ½” diameter 
blower wheel 
•  Neoprene resilient anti-vibration mounted  
•  Low RPM for very quiet performance 
•  Two VEN060I internal blowers can be 
mounted in the following hoods.  This 
requires a dual wire harness (part #10220). 
o
  WSL and WCL hoods 48” or wider 
o
  WER 60” wide hoods 
o
  PSL 66” wide hoods 
 
 
 
Ventilator Motor Ratings* 
Hoods without Heat Lamps: 
2.8 Amps @ 120 V AC, 60 Hz 
Hoods with Heat Lamps: 
7.2 Amps @ 120 V AC, 60 Hz 
*For maximum power supply required, refer to 
hood series selected. 
 
Ventilator Carton Weight: 
VEN060I = 23 lbs.     
 
 
 
 
9     "
3/
4
9    "
1/
4
14"
   
 
 
 
UL
UL
LISTED 7Z66   C
 
When installed in Wind Crest hoods 
 
 
 
 
 
 
 
 
 
 
VEN060I