White Rodgers CAZ-2 Zone Plus Control Panel Catalog

Page of 1
CZ-4 MASTER ZONE CONTROL PANEL, 
CMM-3 MINI ZONING PANEL,
CAZ-2 ZONE PLUS PANEL
Master and Zone Plus Panels Control Zone Thermostats and
Zone Dampers
FEATURES
• Select models compatible with Single Stage, Multi-Stage and Heat Pump systems.
• CZ-4 panel accepts up to 4 Zones, Zone Plus provides for an unlimited number
  of zones in increments of 2.
• Individual zone indication lights.
• Indicator LED’s monitor system operation.
• Dip switch settings and built-in stage timer to quickly customize system control
  functions.
SPECIFICATIONS
Dimensions. . . . . . . . . . . . . . . . . .   7
5
/
8
x 7
1
/
4
x 1
3
/
8
Connections . . . . . . . . . . . . . . . . .    Push-in terminal blocks
Operating Temperature Rating . . .   0°F to 120°F
Humidity . . . . . . . . . . . . . . . . . . . .    5 to 95% non-condensing
Voltage . . . . . . . . . . . . . . . . . . . . .    24 Volts, 50 / 60 Hz
ZONING
ZONE CONTROL PANELS
ANTI-FREEZE UP CONTROL
TECHNICAL HELP
Zoning Design  . . . . . . . . . . . . . . . . . . . . .   see pages 240-243
Installation and Operation. . . . . . . . . . . . .   see pages 244-247
  Model
  Number 
Description
 
CZ-4K 
Master Zone Control Panel - up to 4  Zones  and use with single stage, multi-stage and heat  
 
 
pumps applications - includes leaving air sensor (CLAS) and transformer (use CAZ-2 for    
 
 
additional zones) 
 
CZ-4 
Master Zone Control Panel Controls up to 4 Thermostats and SPST or SPDT Zone Dampers
 
CAZ-2 
Zone Plus Connects to Master Zone (and Adds up to 2 Thermostats and Zone Dampers)
 
CMM-3K 
2 and 3 Zone Single Stage Zone Panel, includes 24V transformer and CLAS
  CMM-3U 
2 Heat / 1 Cool Heat Pump and Multi-Stage, 1 Heat / 1 Cool Single Stage
 
CMM-3UK  2 Heat / 1 Cool Heat Pump and Multi-Stage, 1 Heat / 1 Cool Single Stage, includes 24V trans- 
 
 
former and CLAS
 
CMM-3 
2 and 3 Zone Single Stage Zoning Panel
 
CLAS 
Leaving Air Sensor for CZ-4
 
COAS 
Optional Outdoor Air Sensor for CMM-3U and CMM-3UK. Measures outdoor temperature and  
 
 
switches the heat from heat pump to fossil fuel furnace when the outdoor temperature falls  
 
 
below the balance point.
  Model
  Number 
Description
 
CAFC 
The CAFC prevents the air conditioning coil from freezing due to low air flow, dirty filters, low
 
 
refrigerant pressure, etc. The CAFC snaps onto the suction line close to the evaporator coil as  
possible and breaks the compressor circuit when the suction line drops below 36
o
F and re- 
make the circuit at 46
o
F. Recommended when by-passing air into the return duct.
CZ-4
CMM-3
?
PAGES
240-247
www.white-rodgers.com