White Rodgers 1F97-1277 Emerson Blue 12" Touchscreen Single Stage Thermostat Installation Instruction

Page of 12
Big Blue Touchscreen Thermostat with 
Automatic Heat/Cool Changeover Option
Installation and Operating Instructions for Model:
 
 APPLICATIONS
1F97-1277 Touchscreen Thermostat
 
 SPECIFICATIONS
Electrical Rating:
 
Battery Power .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   mV to 30 VAC, NEC Class II, 50/60 Hz or DC
 Input-Hardwire   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   20 to 30 VAC
Terminal Load   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   1 .5A per terminal, 2 .5A maximum all terminals combined
Setpoint Range   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   45 to 99°F (7 to 37°C)
Differential (Single Stage)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   Heat 0 .6°F; Cool 1 .2°F
Differential (Multi-Stage)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   Heat 0 .6°F; Cool 1 .2°F
Differential (Heat Pump)   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   Heat 1 .2°F; Cool 1 .5°F
Operating Ambient .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   32°F to +105°F (0 to +41°C)
Operating Humidity   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   90% non-condensing max .
Shipping Temperature Range   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   -4 to +150°F (-20 to +65°C)
Dimensions Thermostat .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   4-9/16"H x 5-13/16"W x 1-3/16"D
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS 
CAREFULLY BEFORE INSTALLING OR OPERATING THIS 
CONTROL COULD CAUSE PERSONAL INJURY AND/OR 
PROPERTY DAMAGE.
Model
 
Programming Choices
1F97-1277
Non-Programmable 5+1+1 Day 7 Day
THERMOSTAT APPLICATION GUIDE
Description
Heat Pump (No Aux . or Emergency Heat)
Yes
Heat Pump (with Aux . or Emergency Heat)
Yes
Systems with up to 3 Stages Heat, 2 Stages Cool
No
Heat Only Systems
Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces
Yes
Cool Only Systems
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
Yes
Wired Remote Temperature Sensor (Indoor/Outdoor)
Yes
Dual Fuel Feature (Heat Pump Mode)
Yes
CAUTION
!
To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.
Index
Page
Installation
2
Wiring Connections
2
Thermostat Quick Reference
4
Installer Configuration Menu
5
Operating Your Thermostat
8
Programming
9
Troubleshooting
12
ATTENTION: MERCURY NOTICE
This product does not contain mercury . However, this 
product may replace a product that contains mercury .
Mercury and products containing mercury must not be 
discarded in household trash . Do not touch any spilled 
mercury . Wearing non-absorbent gloves, clean up any 
spilled mercury and place in a sealed container . For proper 
disposal of a product containing mercury or a sealed 
container of spilled mercury, place it in a suitable shipping 
container . Refer to 
www.thermostat-recycle.org for 
location to send the product containing mercury . 
PART NO. 37-7388A
1241
www.white-rodgers.com
www.emersonclimate.com