INSTALLER/CONFIGURATION MENU
With Heat or A/C selected, press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table 
below. Press Menu to advance to the next menu item. Press 
 or 
 to change a menu item options. 
INSTALLER/CONFIGURATION MENU
Menu
Ref.
HP SS
Press
Button
Displayed 
(Factory Default)
Press 
 or 
 to
select from listed op-
tions
Comments
1
1
1
MENU
(MS 2)
HP 1, HP 2, SS 1
Selects Multi-Stage (MS 2 No Heat Pump), 
 
Heat Pump 1 (HP 1, 1 compressor),
Heat Pump 2 (HP 2, 2 compressor or 2 speed 
compressor), or Single Stage (SS 1)
2
2
2
MENU
(GAS) for SS or MS
ELE
GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
3
3
3
MENU
E (On)
OFF
Selects Energy Management Recovery (EMR)
On or OFF.  (Not available in -non-program-
mable mode)
4
4
MENU
CR Heat (ME)
SL, FA
Selects Adjustable Anticipation, cycle rate, Heat
(This item only appears when MS 2 or SS 1 is 
selected above)
5
4
MENU
CR Heat A/C     
(ME)
SL, FA
Selects Adjustable Compressor Anticipation 
(Heat Pump) This item only appears when 
HP 1, HP 2 is selected above
6
5
5
MENU
CR A/C (ME)
or
CR Aux Heat (FA)
SL, FA
SL
Selects Adjustable Anticipation, cycle rate, cool 
(when MS 2 or SS 1 is selected above.) or
Selects the cycle rate for Auxiliary stage (when 
HP 1 or HP 2 is selected above)
7
6
6
MENU
CL (OFF)
CL On
Compressor Lockout Time
8
7
7
MENU
 
Heat A/C Off 
or
Aux Heat A/C Off
Heat A/C Off,
Heat Off with Fan icon,
Heat Off without Fan icon
A/C Off
System Mode Confi guration
with Automatic Changeover capability
9
8
8
MENU
CO (OFF)
CO On
Selects Compressor Optimization
10
9
9
MENU
dL (On)
dL OFF
Selects Display Light On or OFF
11
10
10
MENU
0 HI
(current temperature)
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
12
11
11
MENU
°F
°C
Selects Fahrenheit/Celsius Temperature Display
13
12
12
MENU
P (0)
7
Defaults to P (0) non-programmable
 P (7) is 7-day programming 
14
13
13
MENU
PS (2)
4
Selects Program periods per day: 
4 = Morn, Day, Eve, Night
2 = Day, Night
15
14
MENU
Heat FA (On)
OFF
Fast Heat option may be disabled by
selecting OFF. NA to SS or HP1 confi g.
16
15
14
MENU
A/C FA (On)
OFF
Fast Cool option may be disabled by
selecting OFF. NA to SS or HP1 confi g.
17
16
15
MENU
dS (On)
Off
Selects Automatic Daylight Saving Time option
18
17
16
MENU
HL Heat
(99)
62 to 98
Select's Limited HEAT Range
19
18
17
MENU
LL A/C
(45)
46 to 82
Select's Limited A/C Range
20
19
MENU
dF (0)
1 to 9
Selects dF (dual Fuel) setting. 0 is Off
(If dual Fuel option is required, a selection of 5 
is recommended)
MENU
Cd
(60)
0 to 99
Selects compressor delay in seconds when dF 
is greater than 0
21
20
18
MENU
A/C On (o)
Heat On (b)
Selects operation of the reversing valve terminal 
(O/B) output as an O or B terminal