White Rodgers 1F89-211 White-Rodgers 80 Series Heat Pump Thermostat Installation Instruction

Page of 8
CAUTION
!
To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.
This thermostat is intended for use with a low voltage system; 
do not use this thermostat with a line voltage system. If in doubt 
about whether your wiring is millivolt, line, or low voltage, have 
it inspected by a qualified heating and air conditioning contrac-
tor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes 
and ordinances.
This control is a precision instrument, and should be handled 
carefully. Rough handling or distorting components could cause 
the control to malfunction.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
 
 DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the  
technology of a solid-state microcomputer to provide precise 
temperature control.
Features:
•  Simultaneous heat and cool setpoint storage
•  Setpoint storage in case of power loss
•  Pre-set temperature control
•  LCD continuously displays setpoint and room temperature
•  Continuous Backlit display option
•  °F/°C convertibility
•  Temperature range 45° to 90°F
•  R, C, Y, W2, G, O/B, E, and L terminals for single or two-
transformer systems
•  Optional "AA" batteries to provide continuous temperature
display during loss of AC power
 
 SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating: 
20 to 30 VAC 50/60 Hz. or D.C. 
0.05 to 1.0 Amps (Load per terminal) 
 
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
 
 
45°F to 90°F (7°C to 32°C) 
Operating Ambient Temperature Range: 
32°F to 105°F 
Operating Humidity Range: 
0 to 90% RH (non-condensing) 
Shipping Temperature Range: 
-4°F to 149°F
APPLICATIONS
For use with:
•  Standard heat pump systems with electric, gas or oil Aux
heat with 24 VAC HOT and COMMON available
•  Single-stage heat pump systems with no Aux heat with
24 VAC HOT and COMMON available
DO NOT USE WITH:
•  Millivolt systems
•  Systems exceeding 30 VAC and 1.5 amps
•  3-wire zoned hydronic heating systems
1F89-211
Non-programmable Electronic Digital  
Heat Pump Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
 
 PRECAUTIONS
WARNING
!
Do not use on circuits exceeding specified voltage. 
Higher voltage will damage control and could cause 
shock or fire hazard.
Do not short out terminals on gas valve or primary 
control to test. Short or incorrect wiring will damage 
thermostat and could cause personal injury and/or 
property damage.
Thermostat installation and all components of the 
system shall conform to Class II (current limited) 
circuits per the NEC code. Failure to do so could cause 
a fire hazard.
Operator:  Save these instructions for future use!
PART NO. 37-6233G
Replaces 37-6233F
1502