White Rodgers 1F78-151 White-Rodgers 70 Series Single Stage Thermostat Installation Instruction

Page of 16
www.white-rodgers.com
3
 REMOVING OLD THERMOSTAT 
         CONTINUED FROM FIRST PAGE
ATTENTION! This product does not contain mercury. However, this 
product may replace a unit which contains mercury.
Do  not  open  mercury  cells.  If  a  cell  becomes  damaged,  do  not 
touch any spilled mercury. Wearing non-absorbent gloves, take up 
the spilled mercury and place into a container which can be sealed. 
If a cell becomes damaged, the unit should be discarded.
Mercury must not be discarded in household trash. When the unit 
this product is replacing is to be discarded, place in a suitable con-
tainer. Refer to www.white-rodgers.com for locations to send prod-
uct containing mercury.
4
 MOUNTING AND WIRING
Do not use on circuits exceeding specified voltage. Higher 
voltage will damage control and could cause shock or fire 
hazard.
Do not short out terminals on gas valve or primary control 
to test. Short or incorrect wiring will damage thermostat 
and could cause personal injury and/or property damage. 
Thermostat installation and all components of the system 
shall conform to Class II circuits per the NEC code.
Electric Heat or Single-Stage 
Heat Pump Systems
This thermostat is configured from the factory to operate a heat/
cool,  fossil  fuel  (gas,  oil,  etc.),  forced  air  system.  It  is  configured 
correctly  for  any  system  that  DOES  NOT  require  the  thermostat 
to energize the fan on a call for heat. If your system is an electric 
or  heat-pump  system  that  REQUIRES  the  thermostat  to  turn  on 
the fan on a call for heat, locate the 
GAS/ELECTRIC switch (see 
fig. 1) and switch it to the 
ELECTRIC position. This will allow the 
thermostat to energize the fan immediately on a call for heat. If you 
are  unsure  if  the  heating/cooling  system  requires  the  thermostat 
to control the fan, contact a qualified heating and air conditioning 
service person.
Hydronic (Hot Water or Steam)  
Heating Systems
This thermostat is set to operate properly with a forced-air heating 
system. If you have a hydronic heating system (a system that heats 
with hot water or steam), you must set the thermostat to operate 
properly with your system.
The factory default setting is forced air heat. Clipping jumper W905 
on  the  circuit  board  will  produce  a  longer  heating  cycle  which  is 
normally for hot water or steam (hydronic) systems. Both settings 
produce a very accurate temperature control and can be set to your 
personal preference. As received, the thermostat cycles the system 
just under 1°F. With W905 clipped, the system cycles at approxi-
mately 1.5°F.
Take care when securing and routing wires so they do not 
short to adjacent terminals or rear of thermostat. Personal 
injury and/or property damage may occur.
CAUTION
!
TERMINAL CROSS REFERENCE CHART
New Thermostat
Terminal Designation
Other Manufacturers’
Terminal Designation
RH
RC
G
W
Y
4
R
G
W
Y
RH
R
G
W
Y
M
V
F
H
C
R5
-
G
4
Y6
R
-
G
W
Y
*
*
*  These are four-wire, single-transformer systems.
    Factory installed jumper wire between the 
RH
    and 
RC terminals must remain in place.
Energy Management Recovery (EMR)
This  thermostat    is  set  to  operate  with  EMR.  This  causes  the 
thermostat  to  start  the  heating  or  cooling  system  early  to  have  
the  room  temperature  reach  the  program  setpoint  at  the  time  
the period is to start.
To disable EMR, clip jumper W903 (see Fig. 1).
Attach Thermostat Base to Wall
1.  Remove the packing material from the thermostat. Gently pull 
the  cover  straight  off  the  base.  Forcing  or  prying  on  the  ther-
mostat  will cause  damage  to  the  unit.  If  necessary,  move  the 
electric heat switch (see 
ELECTRIC HEAT SYSTEMS, above).
2.  Connect wires beneath terminal screws on base using appro-
priate wiring schematic (see figs. 2 through 7).
3.  Place base over hole in wall and mark mounting hole locations 
on wall using base as a template.
4.  Move base out of the way. Drill mounting holes.
5.  Fasten base loosely to wall, as shown in fig. 1, using two mount-
ing screws. Adjust until level, and then tighten screws. (Leveling 
is for appearance only and will not affect thermostat operation.) 
If you are using existing mounting holes, or if holes drilled are 
too large and do not allow you to tighten base snugly, use plas-
tic screw anchors to secure subbase.
6.  Push  excess  wire  into  wall  and  plug  hole  with  a  fire-resistant 
material  (such  as  fiberglass  insulation)  to  prevent  drafts  from 
affecting thermostat operation.
Battery Location
This  thermostat  requires  2 “AAA”  alkaline  batteries  to  operate.
  If 
 is displayed, the batteries are low and should be re-
placed. For best results, replace batteries once a year with new pre-
mium brand alkaline batteries such as Duracell
® 
or Energizer
®
. To 
replace the batteries, install the batteries along the top of the base 
(see  fig.  1).  The  batteries  must  be  installed  with  the  positive (+) 
ends to the right.
WARNING
!