White Rodgers 1F51N-619 Single Stage Setpoint Thermostat Catalog
EVAPORATIVE COOLING THERMOSTAT
& CONTROL BOX
Functions as a Switching Device for the Thermostat to Provide
an Even Level of Cooling Plus a Choice of High and Low Speed
Control of the Fan on Evaporative Coolers
FEATURES
• Grey plastic case is lightweight, weather-resistant and meets all code requirements.
• Fully automatic, system designed with a fan delay (approximately 60 seconds) to
pre-wet the cooler pads before the fan starts.
• Separate fan and pump relays. High or low fan speed selection.
• Relay panel is removable from enclosure to facilitate field wiring.
• Integral transformer 120 / 240 VAC to 24 VAC 60 Hz.
SPECIFICATIONS
Dimensions 1F51N-619 . . . . . . . . . . . . . . . . . . . 3
1
/
4
”
H x 4
1
/
2
”
W x 1
5
/
8
”
D
Dimensions 8A18Z-2 . . . . . . . . . . . . . . . . . . . . . 8”H x 6”W x 3”D
Electrical Rating 1F51N-619
. . . . . . . . . . . . . . . 24 VAC (30 VAC maximum)
Fixed anticipator
21D28-6
Model
Package
Number
Consists of:
21D28-6
1F51N-619 / 8A18Z-2
Model
System Switch Positions
Number
Color
Range
Differential System
Fan
1F51N-619 Classic White Scale 1-2-3-4-5 (55 to 95°F) ➀
1°F
Off – Cool – Vent
Hi – Lo
➀
No thermometer
Model
Input
Combined Relay Loads
Pump Relay
Fan Relay
Number
Voltage Full Load Locked Rotor Full Load Locked Rotor Full Load Locked Rotor
8A18Z-2 ➀
120
VAC
16.0A 96.0A 10.0A 60.0A 12.0A 72.0A
240
VAC
8.0A 48.0A 5.0A 30.0A 6.0A 36.0A
➀
U.L. listed
CONTACT RATINGS
EVAPORATIVE
COOLING
www.white-rodgers.com
85
COOLING /
REFRIGERA