Before removing wires from old thermostat’s switching subbase, 
label 
each wire with the terminal designation it was removed from.
1.
  Remove  Old Thermostat:    A  standard  heat/cool  thermostat 
consists of three basic parts:
a.  The cover, which may be either a snap-on or hinge type.
b.  The base, which is removed by loosening all captive screws.
c.  The switching subbase, which is removed by unscrewing the 
mounting screws that hold it on the wall or adaptor plate.
2.
  Shut off electricity at the main fuse box until installation is com-
plete. Ensure that electrical power is disconnected.
3.
  Remove the front cover of the old thermostat. With wires still 
attached, remove wall plate from the wall. If the old thermostat 
has a wall mounting plate, remove the thermostat and the wall 
mounting plate as an assembly.
4.
  Identify each wire attached to the old thermostat using the 
labels enclosed with the new thermostat.
5.
  Disconnect the wires from the old thermostat one at a time. DO 
NOT LET WIRES FALL BACK INTO THE WALL.
6.
  Install new thermostat using the following procedures.
To  prevent  electrical  shock  and/or  equipment  damage, 
disconnect electrical power to the system at the main fuse 
or circuit breaker until installation is complete.
PART NO. 37-6599B
Replaces 37-6599A
1026
Failure  to  follow  and  read  all  instructions  carefully   
before  installing  or  operating  this  control  could  cause 
personal injury and/or property damage
Assemble tools required as shown below.
WIRE CUTTER/STRIPPER
Base
Back of 
Thermostat Body 
RC
G
RH
Y
O
B
W
W904
W905
Mounting
Hole
Mounting
Hole
Figure 1. Thermostat
W904 - clip for Celcius display
W905 - clip for hydronic system
NOTE: Earlier models refer to 37-7006 for jumper locations.
HAND OR POWER 
DRILL WITH 3/16 INCH 
DRILL BIT, IF NEEDED
FLAT BLADE SCREWDRIVER
Installation Instructions for 
Heating & Air Conditioning 
1E78
Non-Programmable Thermostat
 
YOUR THERMOSTAT REPLACES
Typical System Compatibility Chart
1E78
Standard Heat Only Two Wire Gas or Oil Fired Systems (24 volt)
Yes
Electronic Ignition Heat Only Two Wire Systems (24 volt)
Yes
Electronic Ignition Heat Only Gas or Oil Fired Systems (24 volt)
Yes
Standard Heat/Cool Systems (24 volt)
Yes
Heat/Cool Systems Electric Heat (24 volt)
Yes
Heat Only Electric Heat Systems (24 volt)
Yes
Cool Only Systems (24 volt)
Yes
Heat Pump Systems (No Aux. or Emergency Heat)
Yes
Hot Water Zone Heat Only (Two Wire) Systems
Yes
Hot Water Zone Heat Only (Three Wire) Systems
No
Line Voltage Heating or Baseboard 110/240 Volt Systems
No
Millivolt Systems Floor or Wall Furnaces
Yes
12 VDC Mobile Home Application
Yes
Multistage Systems
No
Systems Exceeding 30VAC, 1.5 Amp
No
CAUTION
!
www.white-rodgers.com