White Rodgers 1E65-144 White-Rodgers Digital Line Voltage Thermostat User Manual

Page of 4
PART NO. 37-6862D
Replaces 37-6862C
0839
1E65-144
Non-programmable Electronic Digital Thermostat 
For Line Voltage Applications
INSTALLATION AND OPERATION INSTRUCTIONS
Operator: Save these instructions for future use!
DESCRIPTION
White-Rodgers is a division 
of Emerson Electric Co.
www.white-rodgers.com
The 1E65-144 thermostat has been designed to control electric heating 
systems such as baseboard heaters, radiant fl oors, radiant ceilings 
and convectors.
The adapter plate is used to offset the thermostat when an obstruction 
prevents the thermostat from being mounted directly to the junction 
box.
The thermostat cannot be used with the following:
-  a resistive load under 2 A
-  a resistive load over 16.7 A
-  systems driven by a contactor or a relay (inductive load)
-  central heating systems
Parts 
Supplied: 
  Available 
Accessories:
One (1) thermostat   
 
F61-2642 Adapter Plate
Two (2) 6-32 pan head screws
Supply:   
120/240 VAC, 50/60 Hz
Minimum load:  2 A (resistive only)
 
500 W @ 240 VAC
 
250 W @ 120 VAC
Maximum load:  16.7 A (resistive only)
 
4000 W @ 240 VAC
 
2000 W @ 120 VAC
Setpoint range: 
7°C to 32°C (45°F to 90°F)
Display range: 
0°C to 37°C (32°F to 99°F)
Display resolution:   0.1°C (1°F)
Shipping: 
–20°C to 50°C (-4°F to 120°F)
Approval: 
INSTALLATION
Installation should be done by a qualifi ed heating and air conditioning 
contractor or licensed electrician.
Loosen the screw holding the thermostat cover to the base, open cover 
on hinge and remove the cover.
Temperature 
Display
Temperature 
Adjustment 
Buttons
Light 
Button
System 
Switch
PRECAUTIONS
* Failure to read and follow all instructions carefully before 
installing or operating this control could cause personal injury 
and/or property damage. 
* All wiring must conform to local and national electrical 
codes and ordinances.
WARNING
!
*   To prevent electrical shock, personal injury, and/or equipment 
damage, disconnect electric power to system at main fuse or 
circuit breaker box prior to installation or service.
Screw
SPECIFICATIONS
Optional: Use the adapter plate accessory if you need to offset the 
mounting holes on the junction box. Align and affi x the wall plate to 
the electrical junction box using two 6-32 fl at head screws included 
with the plate.