White Rodgers 1E30 (W) User Manual

Page of 8
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out heat anticipator and could cause personal
injury and/or property damage.
Do not use on circuits exceeding 750 millivolts.
Higher voltage will damage control and could
cause shock or fire hazard.
Printed in U.S.A.
WHITE-RODGERS
R
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO.   63123
(314) 577-1300, Fax (314) 577-1517
9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625
PART NO. 37-5583A
Replaces 37-9587C
9531
These low voltage thermostats are specially designed for
use on self-generating systems. They are non-antici-
pated, enabling them to be used on self-generated sys-
tems having pilot generator outputs from 250 to 750
millivolts.
ATTENTION!
This product contains mercury. There will not be any exposure to mercury under normal conditions of use. This product may replace a unit
which contains mercury. Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing non-absorbent
gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be sealed. If a cell becomes
damaged, the unit should be discarded. Mercury must not be discarded in household trash. When this unit or the unit it is replacing is to be
discarded, place in a suitable container and return to us at WHITE-RODGERS.
If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
CONTENTS
Description .......................................................... 1
Precautions ......................................................... 1
Specifications ...................................................... 2
Installation ........................................................... 2
Select Thermostat Location
Route Wires to Location
Attach Thermostat to Wall
Operation & Maintenance ................................... 3
Calibrating Thermometer
Calibrating Thermostat
PRECAUTIONS
1E30(W)/1F30(W)
Non-Anticipated
Millivolt Room Thermostat
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
Operator:  Save these instructions for future use!
DESCRIPTION
1E30
1F30
CAUTION
!
WARNING
!