White Rodgers 21D83M-843 User Manual

Page of 8
21D83M-843
Integrated Single Stage 
Furnace Control Replacement Kit
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL 
INJURY AND/OR PROPERTY DAMAGE.
 
 DESCRIPTION
 
 PRECAUTIONS
INSTALLATION INSTRUCTIONS
Kit includes:
1 – 50A66-843 ignition control board
1 – Wiring harness (9-pin to 12-pin)
1 – Wiring harness (4-pin to 6-pin)
1 – Mounting panel
4 – Stand-off fasteners
1 – Circuit breaker
1 – 4" blue wire
2 – Wiring diagrams 
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-7337B
Replaces 37-7337A
1244
Installation should be done by a qualified heating and air 
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or 
low voltage, have it inspected by a qualified heating and 
air conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical 
codes and ordinances.
This control is a precision instrument, and should be 
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
Following installation or replacement, follow manufacturer’s 
recommended installation/service instructions to ensure 
proper operation.
WARNING
!
Failure to comply with the following warnings 
could result in personal injury or property damage.
FIRE HAZARD
•  Do not exceed the specified voltage.
•  Replace  existing  control  with  exact  model
and dash number.
•  Protect the control from direct contact with
water (dripping, spraying, rain, etc.).
•  If the control has been in direct contact with
water, replace the control.
•  Label  all  wires  before  disconnection  when
servicing controls. Wiring errors can cause
improper and dangerous operation.
•  Route and secure wiring away from flame.
SHOCK HAZARD
•  Disconnect electric power before servicing.
•  Ensure proper earth grounding of appliance.
•  Ensure proper connection of line neutral and
line hot wires.
EXPLOSION HAZARD
•  Shut off main gas to appliance until installa-
tion is complete.
CAUTION
!
Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage 
the thermostat.
The kit includes the 50A66-843 which is an automatic gas 
interrupted ignition control that employs a microprocessor 
to continually monitor, analyze, and control the proper 
operation of the gas burner, inducer, and fan.
These controls incorporate system fault analysis for quick 
gas flow shut-off, coupled with automatic ignition retry 
upon sensing a fault correction. 
Lennox
White-Rodgers Page
Reference
10M9301 
12L6901
32M8801 
56L8401
50A65-120 
50A65-121
3
PROCEDURE 1
Figure 1, Picture 
1, Table 1, Wiring 
Diagram 5001-6973
24L8501 
63K8901 
97L4801   
50A62-120 
50A62-121 
50A62-820
4
PROCEDURE 2
Figure 1, Picture 
2, Table 2, Wiring 
Diagram 5001-6972
100925-01 
100925-03
17W9201 
23W5101 
30W2501 
69M0801 
69M1501 
83M00 
21D83M-843 
50A66-122 
50A66-123
5
PROCEDURE 3
The 21D83M-843 kit will replace the following Controls:
Follow instructions for replacement of your model num-
ber under the heading 
INSTALLATION.