White Rodgers 37C72U-185 Gas Water Heater Control for LP Gas (Left Hand Threads) Catalog

Page of 1
SPECIFICATIONS
Inlet Size. . . . . . . . . . . . . . . . . . . . . . . . . .  
1
/
2
 NPT
Outlet Size . . . . . . . . . . . . . . . . . . . . . . . .  
1
/
2
inverted flare
Outlet Adapter Fittings . . . . . . . . . . . . . . .  
1
/
2
inverted flare x
3
/
8
 NPT reducer
(furnished with controls noted below) 
  adapter. 
1
/
2
 x 
1
/
2
inverted flare outlet
   
  extension adapter 
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . .  
3
/
4
 NPT, 4
1
/
2
 bulb insertion length
Pilot Connection . . . . . . . . . . . . . . . . . . . .  
1
/
4
compression fitting
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   C.S.A. approved
 
Model 
Pressure Regulation 
Temperature 
Shank
 
Number 
Main Burner 
Pilot 
Range 
Length
 
37C73U-168   3.5” W.C. 
(A.O. Smith Style)
 
4.0” W.C. 
70 to 160°F (21 to 71°C) 
1
1
/
4
GAS WATER HEATER CONTROLS
For Replacement of Standard Gas Water Heater Controls With
Built-In E.C.O. (Energy Cut Off)
FEATURES
• Automatic shut-off of main and pilot gas in the event of pilot failure.
• Pilot gas cock with safe lighting feature and filter.
• Temperature adjustment.
• Manifold pressure tap.
• Built-In E.C.O. (Energy Cut Off) non-cycling high limit.
For use with Natural Gas (Right Hand Threads on Outlet)
 
Model 
Pressure Regulation 
Temperature 
Shank
 
Number 
Main Burner 
Pilot 
Range 
Length
 
37C72U-185  
10.0” W.C. 
10.0” W.C.  70 to 160°F (21 to 71°C) 
1
1
/
4
For use with LP Gas (Left Hand Threads) 
 
Includes Left Hand outlet extension fittings:
1
/
2
 LH x 
1
/
2
LH inverted flare and
1
/
2
 LH x 
3
/
8
LH inverted flare
Outlet adapter fittings included.
37C73U-168
GAS WATER HEATER
CONTROLS
New Product Replacement Gas Water Heater Controls
OEM Model 
Number
Replaced By Model 
Number
Main Burner
Pilot
Temperature 
Range
Shank Length
OEM
37C73U-274
37C73U-171
4.0” W.C. Nat. Gas
4.0” W.C. Nat. Gas
70° - 160°F
2
1
/
2
A. O. Smith
37C73U-640
37C73U-173
4.0” W.C. Nat. Gas
4.0” W.C. Nat. Gas
70° - 160°F
1
1
/
4
A. O. Smith
37C73U-641
37C73U-172
4.0” W.C. Nat. Gas
4.0” W.C. Nat. Gas
70° - 160°F
2
1
/
4
A. O. Smith
37C73U-652
37C73U-174
5.0” W.C. Nat. Gas
5.0” W.C. Nat. Gas
70° - 160°F
1
1
/
4
A. O. Smith
37C73U-836
37C73U-170
4
.
0” W.C. Nat. Gas
4.9” W.C. Nat. Gas
70° - 160°F
1”
Rheem
www.white-rodgers.com
111
111
HYDRONIC /  APPLIANCE