White Rodgers 50A66-743 User Manual

Page of 8
WARNING
Failure  to  comply  with  the following 
warnings  could  result  in  personal  injury 
or property damage.
50A66-743
Integrated Furnace Control
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE 
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL 
INJURY AND/OR PROPERTY DAMAGE.
 DESCRIPTION
Operator: Save these instructions for future use!
INSTALLATION INSTRUCTIONS
The 50A66-743 is an automatic gas interrupted ignition control 
that employs a microprocessor to continually monitor, analyze, 
and control the proper operation of the gas burner, inducer, 
and fan.
Signals interpreted during continual surveillance of the thermostat 
and flame sensing element initiate automatic ignition of the 
burner, sensing of the flame, and system shut-off during normal 
operation.
These controls incorporate system fault analysis for quick gas 
flow shut-off, coupled with automatic ignition retry upon sensing 
a fault correction.
 
 PRECAUTIONS
Installation should be done by a qualified heating and air 
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or low voltage, 
have it inspected by a qualified heating and air conditioning 
contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes 
and ordinances.
This control is a precision instrument, and should be handled 
carefully. Rough handling or distorting components could cause 
the control to malfunction.
Following installation or replacement, follow manufacturer’s 
recommended installation/service instructions to ensure proper 
operation.
CONTENTS
Description  ........................................................  1
Precautions  .......................................................  1
Specifications  ....................................................  2
Installation  .........................................................  3
 
Mounting & Wiring
Operation  ...........................................................  6
System Lockout and Diagnostic Features ........... 7
Troubleshooting ................................................... 8
CAUTION
Do not short out terminals on gas valve or primary 
control. Short or incorrect wiring may damage 
the thermostat.
FIRE HAZARD
•  Do not exceed the specified voltage.
•  Replace existing control with exact model and dash
number.
•  Protect the control from direct contact with water
(dripping, spraying, rain, etc.).
•  If the control has been in direct contact with water,
replace the control.
•  Label all wires before disconnection when servicing
controls. Wiring errors can cause improper and 
dangerous operation.
•  Route and secure wiring away from flame.
SHOCK HAZARD
•  Disconnect electric power before servicing.
•  Ensure proper earth grounding of appliance.
•  Ensure proper connection of line neutral and line
hot wires.
EXPLOSION HAZARD
•  Shut off main gas to appliance until installation is
complete.
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-7473A
1313
50A66-743 Cross Reference Information
Lennox
White-Rodgers 
100925-01
23W51
69M0801        
50A66-122 
100925-02
23W5101
69M15
50A66-123
100925-03
30W25
69M1501 
50A66-743
17W92
30W2501
 
17W9201
69M08