Venting Requirements
Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed 
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended. Do 
not use plastic or metal foil vent.
The vent system must have a damper. If the roof or wall cap 
has a damper, do not use the damper supplied with the range 
hood.
For the most efficient and quiet operation:
Use a straight run or as few elbows as possible.
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent 
between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the 
cap.
The size of the vent should be uniform.
Cold weather installations
An additional back draft damper should be installed to minimize 
backward cold air flow. A nonmetallic thermal break should be 
installed to minimize conduction of outside temperatures as part 
of the vent system. The damper should be on the cold air side of 
the thermal break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of air 
movement. 
The specified CFM varies from locale to locale. Consult your 
HVAC professional for specific requirements in your area.
Venting Methods
This canopy hood is factory set for venting through the roof or 
wall.
An 8" (20.3 cm) round vent system is needed for installation (not 
included). The hood exhaust opening is 8" (20.3 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.
Vent system can terminate either through the roof or wall. To vent 
through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For non-vented (recirculating) installations
If it is not possible to vent cooking fumes and vapors to the 
outside, the hood can be used in the non-vented (recirculating) 
version, fitting an activated carbon filter and the deflector. Fumes 
and vapors are recycled through the top grille.
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.
Maximum equivalent vent length is 50 ft (15.2 m).
12"
(30.5 cm)
12"
(30.5 cm)
21"
(53.3 cm)
min.
36"
(91.4 cm)
min.
30" (76.2 cm) min.
bottom of canopy to
cooking surface
Centerline
Side
cabinet
Side
cabinet
Vent and power
supply cable entry
location
2" (5.1 cm) min.
10
 ¹⁄₂
" (26.7 cm)
Roof Venting
Wall Venting
Non-vented 
(recirculating)
A. Roof cap
B. 8" (20.3 cm) 
round vent
A. Wall cap
B. 8" (20.3 cm) 
round vent
A. Deflector
B. 8" (20.3 cm) 
round vent
Vent piece
8" (20.3 cm) round
45° elbow
2.5 ft
(0.8 m) 
90° elbow
5.0 ft
(1.5 m)