White Rodgers 24A07A-1 Installation Instruction

Page of 8
Type 24A07
 
“Slimline” level-Temp 
SilenT operATor
 
(normally open) 
inSTAllATion inSTrucTionS
 
 DeScripTion
These Level-Temp Silent Operator relays are designed for use 
on electric heating equipment in conjunction with White-Rodgers 
low voltage thermostats. They are especially suitable for use on 
baseboards, wall insert heaters, etc. Some models also have 
an inductive rating to permit them to be used on motor loads 
where a time delay is desired.
Different models of these Silent Operator relays are available 
for voltage inputs of 120, 208, 240, 277, 347 or 600 volts. Since 
these relays are equipped with a self-contained transformer, the 
supply voltage used must agree with the voltage rating of the relay.
When required, two or more of these Silent Operator relays can 
operator:  Save these instructions for future use!
FAilure To reAD AnD FolloW All inSTrucTionS cAreFully BeFore 
inSTAllinG or operATinG THiS conTrol coulD cAuSe perSonAl 
inJury AnD/or properTy DAmAGe.
be operated by one low voltage heating thermostat. These Silent 
Operator relays have been carefully adjusted at the factory. No 
attempt should be made to adjust them in the field.
If in doubt about whether your wiring is millivolt, line, or low 
voltage, have it inspected by a qualified heating and air condi-
tioning contractor, electrician, or someone familiar with basic 
electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes 
and ordinances.
This control is a precision instrument, and should be handled 
carefully. Rough handling or distorting components could cause 
the control to malfunction.
WARNING
!
Do not use on circuits exceeding specified voltages. 
Higher voltages will damage control and could cause 
shock or fire hazard.
CAUTION
!
To prevent electrical shock and/or equipment damage, 
disconnect electric power to system, at main fuse or 
circuit breaker box, until installation is complete.
 SpeciFicATionS
elecTricAl DATA
Switch Action:
 Single-Pole, Single-Throw, normally open
Thermal:  Average time delay – 45 seconds
Ambient Temp.:      -20° to 140°F (-24° to 60°C)
room Thermostat:
Set adjustable heat anticipator at 0.2 Amps. For fixed anticipa-
tion thermostats, use 0.15 to 0.25 Amp. heater.
Type
numBer
inpuT
volTAGe /Frequency
THermoSTAT
currenT
A.c.  reSiSTive
non-inDucTive
A.c. moTor inDucTive
Full loAD
locKeD roTor
24A07A-1
120VAC, 60 Hz
0.2A
25A, 3000W, 120V
16A, 120V
96A, 120V
24A07e-1
208VAC, 60 Hz
0.2A
25A, 5200W, 208V
12A, 208V
72A, 208V
24A07G-1
240VAC, 60 Hz
0.2A
25A, 6000W, 240V
12A, 240V
72A, 240V
24A07Z-1
277VAC, 60 Hz
0.2A
22A, 6000W, 277V
________
________
24A07Z-8
347VAC, 60 Hz
0.2A
17A, 5900W, 347V
________
________
24A07Z-9
600VAC, 60 Hz
0.2A
12A, 7200W, 600V
________
________
 
 precAuTionS
mounting:  Mounting tabs with several break-offs for 2, 3 or 4 hole mounting.