Important Installation and Utility Information
 
Electrical Service: 
110V:  110V, 60 Hz, 2.75 A mp GFCI protected grounded circuit must be used to supply pow er to the 
pedicure spa.  (220V if ordered in 220V configuration) 
220V:  220V, 50/60 Hz, 2.75 Amp GFCI protected grounded circuit must be used to supply pow er to the 
pedicure spa.
 
Water Supply: 
All plumbing connections must conform to local codes. 
Nor mal w ater pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level. 
Maximum operating w ater temperature should not exceed 105
°
 F (41
°
 C) and the maximum supply water 
temperature should not exceed 150
°
 F (65
°
 C).  (In Massachusetts, the maximum supply water temperature 
should not exceed 130
°
 F (54
°
 C)).  Adjust your hot water heater accordingly. 
For hot and cold w ater supply fittings and pow er drain fittings location, see figure 1 below . 
Carefully connect the incoming w ater supply lines to the appropriate fittings located on the back of the 
pedicure spa.  Shut-off valves are recommended.
 
 
The pedicure spa drain must meet local plumbing codes.  Check valve for drain are not provided and 
must be installed by a licensed plumber, if required by Local or State codes. 
**Note: See local and state codes as to what type of drain connection is required to be made.
 
Note:  Not using the supplied bulkhead fittings will result in NO backflow protection.  
Check your Local & State plumbing codes for additional backflow requirements. 
 
Backflow  Protection Devices for Faucets w ith Side Spray: Check valves comply w ith ANSI/ASME 
A112.18.3M, A112.18.1M, CSA B125, and NSF 61
 
 
ANSI/ASME A112.18.3M ( Performance Requirements for Backflow  Protection Devices and Systems in 
Plumbing Fixture Fittings) is applicable to plumbing fixture fittings w ith outlets not protected by an air gap.  
Included in the possible range of applications are fittings with hose connected outlets, fittings w ith pullout 
spout, hand held show ers, shampoo fittings and deck- mounted fittings.  ASME A112.18.3M is now 
referenced in ASME A112.18.1M ( Plumbing Fixture Fittings) and CSA B125.  Check valves are listed to both 
standards w ith the Canadian Standards Association, IA PMO and UL.
 
 
ANSI - American National Standards Institute 
ASME - American Society of Mechanical Engineers 
CSA - Canadian Standards Association 
IAPMO - International Association of Plumbing and Mechanical Officials 
UL - Underwriters Laboratory  
TÜV - Technischer Überwachungs-Verein “Technical Watch-Over Association” 
Hot & Cold supply  
fittings contain Neoperl
®
 
DW15GF check valves.  
See figure 1 for proper 
flow  direction. 
 
Plumbing Connections 
 
 
(does not hav e c heck v alve)
 
 
Back of Pedicure Spa
 
Figure 1