S E R V I C E
12.07.1999 / Page 2
ADP 905/3 WH
Whirlpool Europe
Doc. No: 4812 718 14342
8542 905 01410
Customer Service
Technical data
Dimension
Height
85.0
cm
Width
59.5
cm
Depth
59.2
cm
Weight
58.3
kg
Electronic boards
Service boards
see spare part list
Serial boards
UB
4619 720 80271
CB
096911
Dataset
096901
Succession of programs
Programs
see program diagram
Succession
1a-3b-4b-5a-6a
Program information
Start indicator
Volume (normal program)
Water
Volume
Level
Regeneration
0.3 l
15 mm
Back rinse 3x
1.0 l
68 mm
Prewash
4.8 l
122 mm
Main wash
4.5 l
121 mm
Intermediate rinse 1
4.0 l
120 mm
Intermediate rinse 2
4.0 l
120 mm
Clear rinse
4.0 l
120 mm
Safety / overflow
8.5 l
141 mm
Measuring the level
Remove the coarse sieve, put in a measuring
meter into the sump, measure the hight of the
water level.
Detergent max.
Pre-wash
10
cm
3
Main-wash
45
cm
3
Rinse aid
125
cm
3
6 Dosage steps
1 - 6
ml
Water softener
Saltcontainer
2
kg
Resin container
900
cm
3
Regeneration dosage
300
cm
3
Water pressure
Inlet pressure
0.3-10
bar
Spray pump pressure
0.4
bar
Rotations
Spray pump motor
2800
RPM
Drain pump motor
3000
RPM
Spray arm lower
20 - 40
RPM
Spray arm upper
25 - 35
RPM
Ceiling rotor
45 - 65
RPM
Flow rates / Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
208
lmp/l
Spray pump
~ 70
l/min
Drain pump
16
l/min
Pump height max.
1.1
m
Inlet valve
4.5
l/min
Spray arm lower
33
l/min
Sprayarm upper
27
l/min
Ceiling rotor
10
l/min
Electrical data
Base data
Voltage
220/230
V
Frequency
50
Hz
Total power
2.0-2.2
kW
Fuse
10
A
Motor
Spray pump motor
Voltage
220/230
V
Power consumption
160
W
HI
81
Ω
HA
44
Ω
Capacitor
4
µ
 F