White Rodgers 1F82-0261 User Manual

Page of 12
1
Blue 2” Heat Pump Thermostat
Heat Pump or Single Stage
Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS 
CAREFULLY BEFORE INSTALLING OR OPERATING THIS 
CONTROL COULD CAUSE PERSONAL INJURY AND/OR 
PROPERTY DAMAGE.
APPLICATIONS 
1F82-0261 Thermostat
Model
Programming Choices
1F82-0261
5/1/1 Day Programmable
SPECIFICATIONS 
Electrical Rating:
 
Battery Power .................................................  mV to 30 VAC, 50/60 Hz or DC
 
Input-Hardwire ................................................  20 to 30 VAC
Terminal Load ........................................................  1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ......................................................  45° to 90°F (7° to 32°C)
Differential (Single Stage) ......................................  Heat 0.8°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................  Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient .................................................  32° to +105°F (0° to +41°C)
Operating Humidity ................................................  90% non-condensing max.
Shipping Temperature Range ................................  -40° to +150°F (-40° to +65°C)
Dimensions Thermostat .........................................  3-3/4”H x 4-3/4”W x 1-1/2”D
PRECAUTIONS 
To prevent electrical shock and/or equipment damage, 
disconnect electric power to system at main fuse or 
circuit breaker box until installation is complete.
CAUTION
!
Do not use on circuits exceeding specifi ed  voltage. 
Higher voltage will damage control and could cause 
shock or fi re hazard.
Thermostat installation and all components of the 
system shall conform to Class II (current limited) 
circuits per the NEC code. Failure to do so could cause 
a fi re hazard.
WARNING
!
PART NO. 37-7022B
Replaces 37-7022A
0925
www.white-rodgers.com
YOUR THERMOSTAT  REPLACES
Description
Heat Pump (No Aux. or Emergency Heat)
Yes
Heat Pump (with 1 Aux. or Emergency Heat Stage)
Yes
Standard Heat & Cooling Systems
Yes
Two Stage Heat & Two Stage Cool
No
Standard Heat Only Systems
Yes
Millivolt Heat Only Systems - Floor or Wall Furnaces
Yes
Standard Central Air Conditioning
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
No
Index
Page
Installation
2
Wiring Diagrams
3
Thermostat Quick Reference
4
Installer Confi guration Menu
5
Operation
6
Programming
7
Troubleshooting
9