TROUBLESHOOTING SUGGESTIONS 
SYMPTOM 
 
POWER INDICATOR not lit 
 
 
 
 
 
 
 
 
TANK INDICATOR not lit 
 
STATUS INDICATOR 
flashing 
 
 
 
 
 
 
 
 
 
No water flow from         
dispense nozzle (power   
indicator lit, status indicator 
not flashing) 
 
 
INDUCTIVE HEATER     
operates intermittently 
 
 
 
WATER TANK will not heat 
 
 
 
POSSIBLE CAUSE 
 
Water-Max™ not connected to power 
 
POWER switch OFF 
 
Insufficient water supply 
 
 
Water tank not installed 
 
Tank not properly seated in receptacle 
 
ERROR detected - water pressure 
insufficient 
 
ERROR detected - temperature rise 
between inlet and outlet insufficient 
Tank is full 
 
Tank is sensed as full, but is actually 
low 
 
Tank not properly installed 
 
Internal hi-limit tripping (cooling fan 
dirty or obstructed) 
 
 
 
Tank not properly installed (TANK    
INDICATOR not lit) 
 
Internal damage 
SUGGESTED REMEDY 
 
Check circuit breaker 
 
Press POWER switch to ON 
 
Check water supply turned ON 
And supplying at least 25 p.s.i. 
 
Check tank for proper installation 
 
Check tank for proper installation 
 
Check water supply turned ON 
And supplying at least 25 p.s.i. 
 
Be sure voltage is maintained 
during all phases of operation 
Normal operation 
 
Clean water level probe 
 
 
Check tank for proper installation 
 
Be sure all cooling openings 
and louvers are unobstructed. 
Otherwise contact Authorized 
Wells Service Agency 
 
Check tank for proper installation 
 
 
Contact Authorized Wells     
Service Agency 
RESET Water-Max™:  Turn POWER SWITCH OFF.  Wait 20 seconds. 
Turn POWER SWITCH ON.  If unit resets and status indicator comes on 
without flashing, error was (probably) a low water condition.  Otherwise, 
contact your Authorized Wells Service Agency. 
OPERATIONAL NOTES 
 
Water-Max™ will not operate if water pressure is less than 25 p.s.i.  If Water-Max™ shuts down (status 
light flashes) for no apparent reason, other equipment on the water line may be robbing water pressure 
and/or volume from Water-Max™. 
 
ERROR CODES are displayed on the control board readout, visible through the view port on the upper 
right side of the dispenser.  Refer to Water-Max™ Service Manual p/n 503364 for error code meanings 
and suggested remedies. 
 