Weil-McLain Standing Pilot Cast Iron Gas Boiler CGA25SPDN User Manual
GOLD CGa Gas-Fired Water Boiler — Boiler Manual
12
Part Number 550-101-009/0107
Prepare boiler — placement and setup
2a
Inspect orifices and burners
1. Remove front jacket door. Remove base access panel
(See
&IGURE
, item
, page 62).
4ABLE
below for sizing. (The orifice size is stamped
on the orifice spud barrel.)
Place boiler/crate near
position
position
1.
,EAVE
until installa-
tion site is ready.
2. Move entire crate and pallet next to selected loca-
tion.
3. Remove
crate.
,EAVE
4. Remove boiler from pallet as follows:
a. Tilt left side of boiler up and place a board under
left legs.
b. Tilt boiler the other way and place a board under
right legs.
c. Slide boiler backwards off pallet and into posi-
tion.
$O
a. Shim legs, if necessary.
B
B
Orifice replacement procedure
(when required)
1. Remove access panel.
2. On gas manifold, mark location of main burner with
attached pilot assembly.
3. Remove main burner with attached pilot assembly
from manifold. Remove all remaining burners.
4. Remove and discard all main burner orifices in gas
manifold.
5. Apply a small amount of pipe dope to each of the
new orifices and install in the manifold. Make sure
the orifices are aligned correctly, not cross-threaded
in the manifold tappings.
the orifices are aligned correctly, not cross-threaded
in the manifold tappings.
Use only pipe dope compatible with
propane gas, even if boiler is to be
operated on natural gas. Failure to
comply could result in severe per-
sonal injury, death or substantial
property damage.
propane gas, even if boiler is to be
operated on natural gas. Failure to
comply could result in severe per-
sonal injury, death or substantial
property damage.
6. Reinstall main burner with attached pilot assembly
at location marked on gas manifold. Reinstall all
remaining burners.
remaining burners.
7. Follow check-out procedure, Section
, page 33.
4ABLE
#ORRECTLY
SIZED
3. Level and straighten burners.
"URNERS
4. Reinstall access panel.
$O
Location
Natural gas
U. S.
0-2,000 ft
over 2,000 ft
2.00 mm
(Note 1)
Canada
0-2,000 ft
2,000-4,500
2.00 mm
1.90 mm
Location
Propane gas
U. S.
0-2,000 ft
over 2,000 ft
1.30 mm
(Note 1)
Canada
0-2,000 ft
2,000-4,500
1.30 mm
1.20 mm
Note 1:
For elevations above 2,000 feet, contact your
local Weil-McLain sales office for details.
local Weil-McLain sales office for details.