AT^SFNUR Select the fixed network user rate
The 
 command specifies the Fixed Network User Rate (FNUR) parameter. This parameter is impor-
tant only for mobile originated 14.4 kbit/s UDI calls (
=75) and mobile terminated data calls if the bearer
capability information element is delivered without data bearer service (see 
 and 
 commands). 
Changes are recommended only if a CSD call fails. The choice as to which of the values to use depends on the
GSM network and the location. Users should be aware that even the same operator may apply varying FNUR
configurations in different regions. 
The 
 command has no effect on CSD connections controlled by the Internet Service commands. If
needed for the Internet Services the Fixed Network User Rate can be set in the connection profile. For details
, parameter 
 "fnur".
Syntax
Parameter Description
0
not applicable
1
9.6 kbit/s
2
(P)
14.4 kbit/s
3
19.2  kbit/s
4
28.8  kbit/s
5
38.4  kbit/s
6
48.0  kbit/s
7
56.7  kbit/s
8
64.0  kbit/s