Siemens AC75 User Manual

Page of 569
AC75 AT Command Set  
13.28 AT^SSMSS
s
AC75_ATC_V01.002
Page 401 of 569
10/30/06
Confidential / Released
 
13.28
AT^SSMSS Set Short Message Storage Sequence
The short message storage ''MT'' (see 
) is a logical storage. It consists of two physical storages ''ME''
and ''SM''. This command allows to select the sequence of addressing this storage. 
Syntax
Parameter Description
MT sequence 
0
(&F)
''MT'' storage is ''ME'' then ''SM
1
''MT'' storage is ''SM'' then ''ME''
Note
• The 
 parameter will be stored in non-volatile memory. 
Test Command
AT^SSMSS=?
Response(s)
^SSMSS: 
(list of supported) 
Read Command
AT^SSMSS?
Response(s)
OK
Write Command
Response(s)
OK
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
+
+
+
+
+
+
+
-
+
-
<seq>
(num)