Siemens Camera Accessories 6AU1900-1AB32-0BA0 User Manual

Page of 86
Functions 
 
4.6 Arc Sine Curve 
 
CamTool 
4-18
 
Configuration Manual, 12.2004, 6AU1900-1AB32-0BA0 
2.  Enter the new position and the number of interpolation points in the Position tab and 
click OK. The arc sine curve is shown at the new positions. The arc sine curve is saved 
by the system as an interpolation point table. 
 
Figure 4-14  Position tab 
4.6.3 
Change arc sine curve definition range 
Requirements 
The cam is opened with SIMOTION CamTool. 
Change arc sine curve definition range 
To change the definition range of an arc sine curve:  
1.  Select the arc sine curve in the S diagram (distance diagram). 
The current position of the arc sine curve is shown in the tooltip. 
2.  The arc sine curve is shown with handles. The handles for the definition range are shown 
in green. Point to a green handle. The mouse pointer shows the direction in which you 
can move the handle.